Hydro turbines have complex non-linear dynamics, especially in the presence of large or abrupt load disturbances. In this work, the implementation of a weighted multiple model adaptive control (WMMAC) scheme on a hydro turbine plant was studied. To ensure stability, the system was designed in accordance with the virtual equivalence system and adaptive mixing control criteria. Four candidate linear estimator models were chosen representing 25%, 50%, 75% and 100% load conditions. For each candidate estimator model, a compensator was designed to meet performance requirements under the corresponding candidate load conditions. The performance of three different control structures; the H ∞ , LQG/LTR and PI controllers, used in the WMMAC scheme, were simulated under abruptly changing and smoothly varying load conditions. To account for the transients before reaching synchronous speed, in the first 50 seconds, a no-load compensator was used. From the results, the PI controller produced the best performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.