The purpose of this study was to evaluate a rotational stability of endodontic electronic motors by comparing the changes of rotational speed, depending on the number of usages and with/without static load. Twelve new endodontic electronic motors were used in this study. Non contact type digital tachometer was used for measuring the rotational speed of handpiece. True RMS Multimeter was used for measuring the voltages and the electric currents. All measurements were recorded every 10 seconds during 10 minutes and repeated 9 times. Five repetition was done per each electronic motor. To statistical analysis, student t-test, repeated measures and Scheffe's post-hoc tests were performed. In the same motor group, there was no significant difference in all measurements. In all groups, there was no significant difference in the amount of rotational speed changes depending on the number of usages and with/without static load. In the limitation of this study, the results showed that all kinds of endodontic electronic motors in this study had an established rotational stability. Therefore they could be safely used in root canal treatment with a reliable maintenance of rotational speed, regardless of the number of usages and with/without load. [J Kor Acad Cons Dent 35(4):246-256, 2010]
The purpose of this study was to compare the effect of exponential curing method with conventional curing and soft start curing method on polymerization shrinkage of composite resins.Three brands of composite resins (Synergy Duo Shade, Z250, Filtek Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trilight) were used. 40 seconds curing time was given. The shrinkage was measured using linometer for 90 seconds.The effect of time on polymerization shrinkage was analysed by one-way ANOVA and the effect of curing modes and materials on polymerization shrinkage at the time of 90s were analysed by twoway ANOVA. The shrinkage ratios at the time of 20s to 90s were taken and analysed the same way. The results were as follows:1. All the groups except Supreme shrank almost within 20s. Supreme cured by soft start and exponential curing had no further shrinkage after 30s (p < 0.05). 2. Statistical analysis revealed that polymerization shrinkage varied among materials (p = 0.000) and curing modes (p = 0.003). There was no significant interaction between material and curing mode. 3. The groups cured by exponential curing showed the statistically lower polymerization shrinkage at 90s than the groups cured by conventional curing and soft start curing (p < 0.05). 4. The initial shrinkage ratios of soft start and exponential curing were statistically lower than conventional curing (p < 0.05). From this study, the use of low initial light intensities may reduce the polymerization rate and, as a result, reduce the stress of polymerization shrinkage. [J Kor Acad Cons Dent 32(1): [28][29][30][31][32][33][34][35][36] 2006]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.