Polymerase chain reaction sequence-specific oligonucleotide is commonly used for HLA-typing. We replaced our LabType SSO HD (HD) kits with LabType SSO XR (XR) kits (One Lambda, Inc., Canoga Park, California) for HLA-A, -B, and -DRB1 following acquisition of a LABScan3D analyzer. The XR kits have more bead regions than the HD kits, allowing for an extended number of probes and exon coverage. They are claimed to improve typing resolution and to diminish the number of allele ambiguities, including common and well-documented (CWD) and null alleles to be resolved. We retrospectively selected patients who had their first HLA-typing performed with the HD kits and their second determination with the XR kits between 2015 and 2016. Forty-two patients were selected for HLA-A typing comparison, and 48 for HLA-B and 41 for HLA-DRB1. XR kits significantly decreased the number of allele ambiguities for HLA-A and -B. On the other hand, the improvement was limited for the HLA-DRB1 locus. The XR kits did not resolve all the CWD HLA allele ambiguities, which may be important for organ and/or hematopoietic stem cell transplantations. The XR kits eliminated 88%, 62%, and 27% of null allele ambiguities for HLA-A, -B, and -DRB1 loci, respectively. In conclusion, the XR kits allow for a significant improvement of HLA-typing resolution for HLA-A and -B loci in comparison with HD kits. In contrast, the number of oligonucleotides in the XR HLA-DRB1 kit should be extended to include exon 3 at the very least. It could also be interesting to include oligonucleotides allowing HLA-DRB3, 4, and 5 typing.
Abbreviations: +LR, positive likelihood ratio; AMR, antibody-mediated rejection; anti-dHLA, anti-denatured HLA antibodies; anti-nHLA, anti-native HLA antibodies; AUC, area under curve; B-FCXM, B-lymphocyte flow cytometry crossmatch; DSA, donor-specific antibodies; EDTA, ethylenediaminetetraacetic acid; FCXM, flow cytometry crossmatch; −LR, negative likelihood ratio; MFI, mean fluorescence intensity; NPV, negative predictive value; PPV, positive predictive value; ROC, receiver operating characteristic; SAFB, single antigen flow bead(s); T-FCXM, T-lymphocyte flow cytometry crossmatch.Anti-denatured HLA-Cw antibodies are highly prevalent, whereas anti-native HLA-Cw antibodies seem to lead to random flow cytometry crossmatch results. We aimed to reassess crossmatch prediction for anti-HLA-Cw using 2 types of single antigen flow beads (classical beads and beads with diminished expression of denatured HLA), and to compare the pathogenicity of preformed anti-denatured and anti-native HLA-Cw antibodies in kidney transplantation. We performed 135 crossmatches with sera reacting against donor HLA-Cw (classical beads fluorescence ≥500); only 20.6% were positive. Forty-three (31.6%) were anti-denatured HLA antibodies (beads with diminished expression of denatured HLA fluorescence <300); all were crossmatch negative.The correlation between classical beads fluorescence and the crossmatch ratio was low (ρ = 0.178), and slightly higher with beads with diminished expression of denatured HLA (ρ = 0.289). We studied 52 kidney recipients with preformed anti-HLA-Cw
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.