This paper reviews the factors and criteria for the design of new and the retrofitting of existing dry detention ponds to enhance removal of total suspended solids (TSS) from stormwater. Detention time is discussed as the most important factor affecting TSS removal. Two-stage facilities and multi-level outlet design are important means of enhancing TSS removal in dry ponds. Two dry ponds within the city of Edmonton were selected to evaluate their TSS removal. The level of expected TSS removal is low owing to the relatively short detention times for both ponds. Methods for retrofitting the dry ponds to enhance TSS removal are discussed.Key words: dry pond, stormwater, TSS removal, detention time, retrofitting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.