International audienceIn this paper, a new method based on the continuous wavelet transform is described in order to detect the QRS, P and T waves. QRS, P and T waves may be distinguished from noise, baseline drift or irregular heartbeats. The algorithm, described in this paper, has been evaluated using the Computers in Cardiology (CinC) Challenge 2011 database and also applied on the MIT-BIH Arrhythmia database (MITDB). The data from the CinC Challenge 2011 are standard 12 ECG leads recordings with full diagnostic bandwidth compared to the MITDB which only includes two leads for each ECG signal. Firstly, our algorithm is validated using fifty 12 leads ECG samples from the CinC collection. The samples have been chosen in the "acceptable records" list given by Physionet. The detection and the duration delineation of the QRS, P and T waves given by our method are compared to expert physician results. The algorithm shows a sensitivity equal to 0.9987 for the QRS complex, 0.9917 for the T wave and 0.9906 for the P wave. The accuracy and the Youden index values show that the method is reliable for the QRS, T and P waves detection and delineation. Secondly, our algorithm is applied to the MITDB in order to compare the detection of QRS wave to results of other some works in the literature
International audienceThe electrical field potential of the heart recorded from the thoracic part of the human body is depicted by the electrocardiogram signal. This last one is complex and depends on many factors: Position of heart, thickness of the body skin, surface electrode conductivity, acquisition noise and many others. In clinical use, the ECG signal is analysed using twelve leads but in many works in the literature, the analysis methods of the ECG is based on two leads. We present a new method to delineate QRS complexes and T and P waves from electrocardiogram signal. It is based on the continuous wavelet transform. The method is applied on several leads, recorded simultaneously, to improve the localization of the detection. Indeed, if a delineation method is applied on only one lead with some disturbances in it, the result of the delineation could be affected. As the method proposed here merges the result of several leads, the delineation is less affected by disturbances on few leads. The results from this method and from a doctor in medicine are compared. That shows the good ability to separate waves and the enhancement of delineation accuracy when several leads are used
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.