Stress intensity factor solutions for clamped single edge notched tension (SENT) specimens, including a closed‐form function recently proposed by Zhu along with a function by CanmetMATERIALS referenced in the British Standard BS 8571, have been assessed. Solutions for an SENT specimen with a daylight‐to‐width ratio of 10 have been compared with new finite element results generated in this work to assess their accuracies. The results of this study show that the polynomial proposed by Zhu differs by no more than 0.23% compared with the numerical results over the range of 0.2 ≤a/W ≤ 0.7. The CANMET function differs by no more than 0.69% over the same range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.