An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D 2 [25(OH)D 2 ], 25-hydroxyvitamin D 3 [25(OH)D 3 ], 3-epi-25-hydroxyvitamin D 3 [3-epi-25(OH)D 3 ], and 24R,25-dihydroxyvitamin D 3 [24R,25(OH) 2 D 3 ] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias ≤ |± 5%|. For the 13 unique ligand binding assays evaluated in Published in the topical collection celebrating ABCs 20th Anniversary.
The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at −40 °C prior to distribution and the participants are instructed to store the samples frozen at −20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient-and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays. Keywords 25-Hydroxyvitamin D 3 • 25-Hydroxyvitamin D 2 • Total 25-hydroxyvitamin D • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) • Vitamin D External Quality Assessment Scheme (DEQAS) • Ligand binding assay * Stephen A. Wise
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.