The $$^2{\mathrm{S}}_{1/2}{-}^2{\mathrm{P}}_{{1}/2}$$
2
S
1
/
2
-
2
P
1
/
2
and $$^2{\mathrm{S}}_{1/2}{-}^2{\mathrm{P}}_{{3}/2}$$
2
S
1
/
2
-
2
P
3
/
2
transitions in Li-like carbon ions stored and cooled at a velocity of $$\beta \approx 0.47$$
β
≈
0.47
in the experimental storage ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.
Abstract:In this contribution, we present a wavelength-sensitive method for the detection of extreme ultraviolet (XUV) photon energies between 30 eV and 120 eV. The method is based on 45 • reflectivity from either a cesium iodide-coated or an uncoated metal surface, which directs the XUV beam onto an electron or ion detector and its signal is used to monitor the XUV beam. The benefits of our approach are a spectrally sensitive diagnosis of the XUV radiation at the interaction place of time-resolved XUV experiments and the detection of infrared leak light though metal filters in high-harmonic generation (HHG) experiments. Both features were tested using spectrally shaped XUV pulses from HHG in a capillary, and we have achieved excellent agreement with XUV spectrometer measurements and reflectivity calculations. Our obtained results are of interest for time-resolved XUV experiments presenting an additional diagnostic directly in the interaction region and for small footprint XUV beamline diagnostics.
The and 2S1/2 - 2P1/2 and 2S1/2 - 2P3/2 transitions in Li-like carbon ions stored and cooled at a velocity of β ≈ 0.47 in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths have been obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system used to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry could be resolved and agreement between experiment and theory is confirmed. Nonetheless, the experimental uncertainty is still smaller than that of state-of-the art theory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.