The studied ICD lead with a floating atrial sensing dipole met the predefined safety expectation and demonstrated appropriate atrial sensing performance.
AimTo investigate whether diagnostic data from implanted cardiac resynchronization therapy defibrillators (CRT-Ds) retrieved automatically at 24 h intervals via a Home Monitoring function can enable dynamic prediction of cardiovascular hospitalization and death.Methods and resultsThree hundred and seventy-seven heart failure patients received CRT-Ds with Home Monitoring option. Data on all deaths and hospitalizations due to cardiovascular reasons and Home Monitoring data were collected prospectively during 1-year follow-up to develop a predictive algorithm with a predefined specificity of 99.5%. Seven parameters were included in the algorithm: mean heart rate over 24 h, heart rate at rest, patient activity, frequency of ventricular extrasystoles, atrial–atrial intervals (heart rate variability), right ventricular pacing impedance, and painless shock impedance. The algorithm was developed using a 25-day monitoring window ending 3 days before hospitalization or death. While the retrospective sensitivities of the individual parameters ranged from 23.6 to 50.0%, the combination of all parameters was 65.4% sensitive in detecting cardiovascular hospitalizations and deaths with 99.5% specificity (corresponding to 1.83 false-positive detections per patient-year of follow-up). The estimated relative risk of an event was 7.15-fold higher after a positive predictor finding than after a negative predictor finding.ConclusionWe developed an automated algorithm for dynamic prediction of cardiovascular events in patients treated with CRT-D devices capable of daily transmission of their diagnostic data via Home Monitoring. This tool may increase patients’ quality of life and reduce morbidity, mortality, and health economic burden, it now warrants prospective studies.ClinicalTrials.gov NCT00376116.
Patients with prosthetic heart valves require lifelong oral anticoagulant therapy based on vitamin K antagonists. These patients may need interruption of their anticoagulant therapy if they have to undergo surgery. The clinical challenge is to identify patients who can safely undergo surgery while continuing their vitamin K antagonist treatment and those who have to take short-acting heparin as part of a bridging therapy. Here we present a case of a patient with a prosthetic mitral valve whose oral anticoagulant therapy was unnecessarily discontinued by the GP prior to an upcoming cataract surgery. As a result, the patient developed thrombosis of the prosthetic mitral valve which needed to be surgically replaced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.