(68)Ga-DOTA-TOC PET may be superior to (18)F-DOPA PET and diagnostic CT in providing valuable information for pretherapeutic staging of extra-adrenal PGL, particularly in surgically inoperable tumours and metastatic or multifocal disease.
BackgroundTumor volume may serve as a predictor of response to radiochemotherapy (RCT) in head and neck squamous cell carcinoma (HNSCC). Computer assisted tumor volumetry requires time-consuming slice-by-slice manual or semi-automated segmentation. We questioned how accurately primary tumor and suspect cervical lymph node (LN) volumes can be approximated by the maximum tumor diameters in three dimensions.MethodsIn contrast-enhanced diagnostic CT scans of 74 patients with incident advanced HNSCC, manual slice-by-slice segmentation volumetry of primary tumor, total- and largest suspect cervical LN served as the reference method. In the same scans, maximum orthogonal diameters were measured using the distance measurement tool in standard visualization software in axial and coronal sections. From these diameters, approximate volumes were calculated using the cubic and ellipsoid formula. A second segmentation volumetry was performed in contrast enhanced radiotherapy-planning CT scans obtained prior to primary concurrent RCT 24 days (+/− 13 days) following the initial diagnostic CT scans. Intraclass correlation coefficients and Bland-Altman analyses were used to compare results.ResultsSlice-by-slice manual segmentation volumetry of primary and LN volumes revealed a lognormal distribution and ranged from 0 to 86 ml and 0 to 129 ml, respectively. Volume approximations in diagnostic CT scans with the ellipsoid formula resulted in an −8 % underestimation of tumor volumes (95 % CI −14 % to −1 %; p = 0.022) and an −18 % underestimation of suspect cervical LN volumes (95 % CI −25 % to −12 %; p = 0.001). Inter rater intraclass correlation for primaries was 0.95 (95 % CI +0.92 to +0.97; p = 0.001), and intra rater intraclass correlation was 0.99 (95 % CI +0.98 to +0.99; p = 0.001). The cubic formula resulted in pronounced overestimation of primary and LN volumes. Primary tumor volumes obtained by the second segmentation volumetry in radiotherapy-planning CT scans obtained on average 24 days following the initial volumetry resulted in larger primary tumor volumes (mean bias +28 %, 95 % CI +14 % to +41 %; p = 0.001). Tumor volume increase correlated with time between the diagnostic and planning CTs (r = 0.24, p = 0.05) and was approximately 1 % per day.DiscussionEllipsoid approximations of tumor and lymph node volumes in HNSCC using maximum orthogonal diameters underestimates volumes based on segmentation in multiple slices. Due to time difference and safety margins, segmented volumes in radiotherapy-planning CT scans tend to be larger than in diagnostic CT scans.ConclusionEllipsoid approximations of tumor and lymph node volumes in HNSCC are easily available from diagnostic CT scans. Volume estimates are applicable over a wide range of tumor and LN sizes and may be useful in clinical decision-making and oncologic research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.