Microincisional 23-gauge pars plana vitrectomy with ILM peeling and gas tamponade is effective in the treatment of myopic traction maculopathy, with low postoperative complications. Globally, both BCVA and macular thickness improved significantly during the follow-up period. However, greater visual acuity improvements were only seen in eyes with preoperative BCVA equal to or better than 20/63 Snellen equivalent. Some concerns remain about the risk of macular hole formation after ILM peeling. Further studies are necessary to investigate this issue.
Conclusions-The treatment of subfoveal CNV in highly myopic patients by surgical removal by vitrectomy does not achieve any significant improvement of the BCVA. (Br J Ophthalmol 2001;85:1041-1043 High myopia (more than −6 dioptres and/or longer than 26 mm of axial length), is the seventh most common cause of legal blindness in adults in the USA.
PURPOSE: To analyze the risk of retinal detachment in highly myopic patients who underwent implantation of phakic intraocular lenses (PIOLs).
METHODS: In a retrospective, non-comparative, interventional case series, the occurrence of retinal detachment was analyzed in 522 consecutive highly myopic eyes (323 patients) that underwent PIOL implantation. Treatment and results were reviewed. Parameters evaluated were best corrected visual acuity before and after retinal detachment surgery and time between refractive surgery and retinal detachment.
RESULTS: Fifteen (2.87%) eyes presented with retinal detachment after PIOL implantation, with a mean time between surgery and detachment of 24.4 ±24.4 months (range: 1 to 92 months). The risk of retinal detachment in patients with high myopia corrected by PIOL implantation was 0.57% at 3 months, 1.64% at 12 months, 2.73% at 36 months, and 4.06% at 92 to 145 months (Kaplan-Meier analysis). A comparative study between the group of patients with retinal detachment and the remaining patients without retinal detachment was performed. Differences were found in axial length (30.65±1.97 vs 29.51±2.02; P=. 028, one factor-analysis of variance test).
CONCLUSIONS: The risk of retinal detachment in eyes implanted with phakic lenses for the correction of high myopia is higher in eyes with axial length >30.24 mm. [J Refract Surg. 2006;22:247-252.]
Intravitreal bevacizumab showed a morphologic improvement and stable VA in a patient with AFVD. Further case series are required to confirm this observation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.