The objective of the present work is to assess experimentally the performance characteristics of a R410A domestic air conditioner under different in-door operating conditions. In order to achieve this objective, a test facility of the investigated system is developed and experiments are conducted. Experimental results on R410A air conditioning system are obtained over a wide range of in-door operating conditions. Experimental results confirmed that the cooling capacity, compressor power and COP increase by 90.9%, 5.2% and 81.5%, respectively, as air humidity ratio increases from 8 to 25.5[Formula: see text]gw kg[Formula: see text]. The cooling capacity, condenser heat load, compressor power and COP increase by 7.2%, 6.1%, 2.8% and 4.1%, respectively, when the evaporator air inlet temperature increases from 28[Formula: see text]C to 34[Formula: see text]C for a given humidity ratio. COP increases by 25.6% while pressure ratio decreases by 2.5% as the air volume flow rate increases from 400 to 550[Formula: see text]m3 h[Formula: see text].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.