The article presents a clinical observation of successful treatment of a patient with intrahospital hemodynamically significant pulmonary embolism, which frolicked in the first 35 hours after bone-plastic trepanation in the right temporal-parietal region for the purpose of microsurgical excision of arteriovenous malformation of the right parietal lobe.
The importance of relieving paroxysms of fibrillation and atrial flutter is determined by a huge number of patients suffering from this pathology and its recurrent course.Objective: To create an algorithm for the treatment of patients with atrial fibrillation and atrial flutter by comparing the efficacy and safety of drug-induced rhythm conversion with amiodarone, propafenone, procainamide, niferidil and electropulse therapy.Material and methods. Heart rate conversion was performed in 299 patients. Amiodarone was used as a drug for therapy in 93 patients, propafenone in 34, procainamide in 52, and niferidil in 50. 70 patients underwent electropulse therapy. A comparative analysis was carried out to establish the effectiveness and safety of heart rate conversion by these methods.Results. The effectiveness of conversion rhythm in atrial fibrillation with the help of electropulse therapy, propafenone, niferidil, procainamide and amiadarone has been established, which is 90,3%, 82,4%, 77,4%, 72,5% and 70.5%, respectively. It was also found that the use of electro-pulse therapy and niferidil, in which sinus rhythm recovery occurs in 94.4% and 78.9%, respectively, against 58.3% and 26.7% of patients receiving procainamide and amiodarone, respectively, is most appropriate for the relief of atrial flutter. Often, when using niferidil, ventricular extrasystole and prolongation of the QT interval during electrography developed in comparison with patients of other groups. Ventricular tachycardia, including the "pirouette" type, sinoatrial blockade, AV blockade of various degrees, were also slightly more often registered in these patients.Conclusions. In order to stop atrial fibrillation, there are no differences between medications, and it is better to perform rhythm conversion with atrial flutter with niferidil or electro-pulse therapy.
The discrepancy of echocardiographic signs of right ventricular overload with the clinical picture and the level of plasma troponin concentration may underestimate the severity of the condition and lead to an inadequate choice of therapy, since all these parameters are currently determining the tactics of treatment of patients.Objective: to assess the prevalence and clinical characteristics of patients with pulmonary embolism with inconsistency of clinical, laboratory and instrumental picture.Material and methods. The course of the disease of 456 patients with pulmonary embolism was analyzed. 21 patients had a fatal outcome, the rest recovered. All patients underwent general clinical and biochemical blood tests, determination of the level of D-dimer and troponin, electrocardiography, echocardiography, ultrasound of the veins of the lower extremities, CT angiopulmonography, analysis of the results obtained.Results. It was found that among patients with high- and moderate-risk pulmonary embolism, women more often than men have an increase in the plasma concentration of troponin levels by 2.4 times, as well as a 3-fold discrepancy in the clinical and laboratory-instrumental picture with the presence of signs of right ventricular overload according to echocardiography data, which appear in dynamics. The phenomenon of "delayed echocardiography signs of overload of the right heart" is recorded in 0.8% of all patients with pulmonary embolism. At the same time, in patients with a high risk of early pulmonary embolism – associated death, its occurrence is 2.1%, and in patients with a moderately high risk – 4.4%. When comparing the prevalence of clinical and instrumental symptoms of pulmonary embolism in these patients with the data of patients with high and moderate risks of early death from pulmonary embolism, no statistically significant differences were found, including in terms of echocardiography in dynamics. The delay of еchocardiography signs of overload of the right parts of the heart" by 12–36 hours from the clinical picture, including in patients with hemodynamically significant pulmonary embolism, can be detected only with a series of еchocardiography, which allows, if necessary, timely review scope of treatment. In patients with pulmonary embolism with a pronounced lesion of the pulmonary artery, due to the rapidly progressing course of the disease, it is possible that the еchocardiography criteria of the disease do not have time to develop. In this case, an assessment of the stroke volume may play an important role, hover this parameter is non-specific for this disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.