1,3-Thiazolidin-4-one derivatives with a exocyclic C=C double bond in position 2 of the hetero ring have a wide spectrum of biological activity, but their fungicidal activity has not been studied as much as it should be. This paper presents a simple and convenient approach for obtaining potential antifungal agents based on 2-(4-oxo-1,3-thiazolidin-2-ylidene)acetamides. The first examples of evaluating the fungicidal activity of 8 obtained compounds on 8 strains of phytopathogenic fungi are presented. A highly active compound 4e with EC50 of 0.85 and 2.29 µg/mL against A. solani and P. lingam, respectively, was found to be promising for further study.
Incentive spirometry is one of the most common methods used for respiratory rehabilitation in the early period after cardiac surgery. Inspiratory capacity values, obtained by a patient using spirometer, are not reliably trusted.Objectives. To compare volumetric parameters measured with incentive spirometer and results obtained with bedside ultrasound-based spirometer to assure the feasibility of the use of incentive spirometry to assess the inspiratory capacity and effectiveness of postoperative respiratory rehabilitation.Materials and methods. The study included 50 patients after elective cardiac surgery. Pulmonary rehabilitation involved the use of various respiratory therapy methods. Spirography was performed before and after each session. Both approaches were used simultaneously to obtain the spirometry maximum inspiratory capacity (SMIC) with a bedside ultrasonic spirography and maximum inspiratory capacity (MIC) index using an incentive spirometer. Patient’s discomfort and adverse events during the procedures were recorded.Results. The absolute values of the MIC measured before and after each session by the two methods were dissimilar, however, the average increment values (Δ) did not show statistically significant differences. The correlation analysis revealed a strong positive statistically significant relationship between Δ SMIC and Δ MIC (r = 0.74 before the session, r = 0.79 after the session, r = 0.77 across the whole data set, p<0.01), also consistent with the Bland-Altman analysis, evidencing that more than 95% of all values fell within ± 1.96 SD of the mean difference. The inspiratory spirometry method showed good diagnostic accuracy (sensitivity 87%, specificity 85%, area under the curve (AUC) 0.8 (95% CI: [0.76;0.83]), p<0.001). Refusals of procedure were more often documented with ultrasonic spirography.Conclusion. The increment in the inspiratory capacity index measured with incentive spirometer shows good agreement with ultrasonic spirography measurements. Therefore, incentive spirometry can be reliably used to assess the effectiveness of respiratory rehabilitation interventions in cardiac surgery patients during early postoperative period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.