A method of measuring the power line wire sag using optical sensors that are insensitive to high electromagnetic fields was proposed. The advantage of this technique is that it is a non-invasive measurement of power line wire elongation using a unique optomechanical system. The proposed method replaces the sag of the power line wire with an extension of the control sample and then an expansion of the attached chirped fiber Bragg grating. This paper presents the results of the first measurements made on real aluminum-conducting steel-reinforced wire, frequently used for power line construction. It has been shown that the proper selection of the CFBG (chirped fiber Bragg grating) transducer and the appropriate choice of optical parameters of such a sensor will allow for high sensitivity of the line wire elongation and sag while reducing the sensitivity to the temperature. It has been shown that with a simple optomechanical system, a non-invasive measurement of the power line wire sag that is insensitive to temperature changes and the influence of high electromagnetic fields can be achieved.
This study analyzes the existing methods for studying nasal breathing. The aspects of verifying the results of rhinomanometric diagnostics according to the data of spiral computed tomography are considered, and the methodological features of dynamic posterior active rhinomanometry and the main indicators of respiration are also analyzed. The possibilities of testing respiratory olfactory disorders are considered, the analysis of errors in rhinomanometric measurements is carried out. In the conclusions, practical recommendations are given that have been developed for the design and operation of tools for functional diagnostics of nasal breathing disorders. It is advisable, according to the data of dynamic rhinomanometry, to assess the functioning of the nasal valve by the shape of the air flow rate signals during forced breathing and the structures of the soft palate by the residual nasopharyngeal pressure drop. It is imperative to take into account not only the maximum coefficient of aerodynamic nose drag, but also the values of the pressure drop and air flow rate in the area of transition to the turbulent quadratic flow regime. From the point of view of the physiology of the nasal response, it is necessary to look at the dynamic change to the current mode, given the hour of the forced response, so that it will ensure the maximum possible acidity in the legend. When planning functional rhinosurgical operations, it is necessary to apply the calculation method using computed tomography, which makes it possible to predict the functional result of surgery.
In this paper, we present a method for the simultaneous measurement of rotation and displacement or rotation and bending using single tilted fiber Bragg grating (TFBG). The insensitivity of the proposed system to temperature changes and the stretching direction of the fiber section in the sensing structure have been demonstrated. The experimentally determined sensitivities for rotation, displacement and bending are as follows: -0.0018 1/deg., 0.0054 nm/mm, and -0.055 1/mm over the measurement ranges of approximately 25-80 degrees, 34-74 mm, and 26.4-20 mm, respectively. The presented measurement system is versatile due to the ability to tune the measurement range by changing the fiber-loop radius.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.