This work described the development and the full validation of a precise, sensitive and accurate assay. After validation, this new assay was successfully applied to routine toxicological analysis.
Potential under- or overdose of antibiotics may occur in intensive care units due to high variability in plasma concentrations. The risk is either treatment failure or toxicity. Thus, therapeutic drug monitoring of antibiotics may guide dosing adjustment, maximising antibacterial efficacy and minimising toxicity. The aim of this study was to develop and validate a method for the analysis of 15 antibiotics including beta-lactams, linezolid, fluoroquinolones, daptomycin, and clindamycin to have a complete panel in the management of infections. We proposed to develop a fast, sensitive, and quantitative method for the analysis of 15 antibiotics using ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometer (UPLC-MS/MS) technology. this method required only 100 µL of plasma and consisted of a rapid liquid–liquid deproteinisation using methanol. Calibration curves ranged from 0.078 to 500 mg/L depending on the molecules, and were defined according to a therapeutic range. Inter- and intra-assay precisions values were less than 15%. This work described the development and the full validation of a precise, sensitive and accurate assay using UPLC-MS/MS technology. After validation, this new assay was successfully applied to routine therapeutic drug monitoring.
Adrenocortical carcinoma (ACC) is an aggressive malignancy of the adrenal gland. Mitotane (o,p'-DDD) is the most effective chemotherapy for ACC. According to the literature, mitotane plasma trough concentrations within 14-20 mg L are correlated with a higher response rate with acceptable toxicity. Therapeutic drug monitoring (TDM) of mitotane is therefore recommended. The aim of this study was to propose a robust and simple method for mitotane quantification in plasma. The validation procedures were based on international guidelines. Sample preparation consisted of a single protein precipitation with methanol using 100 μL of plasma. The supernatant was submitted to liquid chromatography coupled with ultra-violet detection at 230 nm. Mitotane retention time was 7.1 min. The limit of detection was 0.1 mg L and the limit of quantification was 0.78 mg L . The assay demonstrated a linear range of 0.78-25 mg L with correlation coefficients (r ) at 0.999. Inter- and intra-assay precision was <4.85%. Evaluation of accuracy showed a deviation <13.69% from target concentration at each quality control level. This method proved easy and rapid to perform mitotane TDM and required a small volume of sample. It was successfully applied to routine TDM in our laboratory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.