3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a "one-stop-shop" solution in female infertility diagnostic work-up.
Background The effect of gadolinium-based contrast agents on diffusion-weighted imaging (DWI) measurements of breast lesions is still not clear. Purpose To investigate gadolinium effects on DWI and apparent diffusion coefficient (ADC) in breast lesions and normal parenchyma with 3 Tesla contrast-enhanced MRI. Material and Methods Pre- and post-contrast DWI (b = 0 and b = 1000 s/mm) were acquired in 47 patients. Measured ADC values, pre- and post-contrast T2 signal intensity (T2 SI) and contrast-to-noise ratio (CNR) were compared with Wilcoxon signed-rank and rank-sum test ( P < 0.05). Results Post-contrast ADC was reduced only in malignant lesions (-34%), T2 SI was reduced both in malignant (-50%) and benign (-36%) lesions. Post-contrast CNR was reduced in all groups except for benign lesions. Conclusion Gadolinium-based contrast agent causes a significant reduction in ADC values of malignant breast lesions.
BackgroundCurrent magnetic resonance imaging (MRI) techniques for measuring extraocular muscle (EOM) volume enlargement are not ideally suited for routine follow-up of Graves’ ophthalmopathy (GO) because the difficulty of segmenting the muscles at the tendon insertion complicates and lengthens the study protocol.PurposeTo measure the EOM sampled volume (SV) and assess its correlation with proptosis.Material and MethodsA total of 37 patients with newly diagnosed GO underwent 3-T MRI scanning with iterative decomposition of water and fat (IDEAL) sequences with and without contrast enhancement. In each patient, the three largest contiguous coronal cross-sectional areas (CSA) on the EOM slices were segmented using a polygon selection tool and then summed to compute the EOM-SV. Proptosis was evaluated with the Hertel index (HI). The relationships between the HI value and EOM-SV and between HI and EOM-CSA were compared and assessed with Pearson’s correlation coefficient and the univariate regression coefficient. Inter-observer and intra-observer variability were calculated.ResultsHI showed a stronger correlation with EOM-SV (P < 0.001; r = 0.712, r2 = 0.507) than with EOM-CSA (P < 0.001; r = 0.645 and r2 = 0.329). The intraclass correlation coefficient indicated that the inter-observer agreement was high (0.998). The standard deviation between repeated measurements was 1.9–5.3%.ConclusionIDEAL sequences allow for the measurement EOM-SV both on non-contrast and contrast-enhanced scans. EOM-SV predicts proptosis more accurately than does EOM-CSA. The measurement of EOM-SV is practical and reproducible. EOM-SV changes of 3.5–8.3% can be assumed to reflect true volume changes.
We report a rare case of left liver lobe absence in an 80-year-old male patient discovered during an MRI scan. The main imaging features of this condition are briefly reviewed, together with its pathogenesis and the most common associations and differential diagnoses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.