Three-dimensional (3D) printing is increasingly being utilized in the dental field. After fabricating a prosthesis using a 3D printed resin, a post-curing process is required to improve its mechanical properties, but there has been insufficient research on the optimal post-curing conditions. We used various 3D printed crown and bridge materials in this study, and evaluated the changes in their properties according to post-curing time by evaluating the flexural strength, Weibull modulus, Vickers hardness, color change, degree of conversion, and biocompatibility. The obtained results confirmed that the strength of the 3D printed resin increased when it was post-cured for 60–90 min. The Vickers hardness, the degree of conversion, and biocompatibility of the 3D printed resins increased significantly around the beginning of the post-curing time, and then increased more gradually as the post-curing time increased further. It was observed that the color tone also changed as the post-curing time increased, with some groups showing a ΔE00 value of ≥ 2.25, which can be recognized clinically. This study has confirmed that, after the printing process of a 3D printed resin was completed, a sufficient post-curing time of at least 60 min is required to improve the overall clinical performance of the produced material.
The purpose of this study was to examine and compare color and translucency stability of three-dimensional (3D) printable dental materials for crown and bridge restorations. Five different materials were investigated, and twelve disc-shaped specimens of two different thicknesses (1 and 2 mm) were prepared using a digital light processing 3D printer. Color measurements were made according to the CIELAB color scale (L*, a*, and b*) using a spectrophotometer 1 h, 1 day, 1 week, one month, and six months after post-curing of the materials, and the translucency parameter (TP) was calculated. The L*, a*, b*, and TP values were compared among the different materials and storage periods using repeated measures analysis of variance. Color and translucency changes of the specimens after the different storage periods were compared with 1 h measurements to determine whether they exceeded clinically perceivable thresholds. The L*, a*, b*, and TP values showed significant differences according to the storage periods, as well as among the materials. Until one month, some materials demonstrated distinct color differences, while others showed small color differences below a clinically perceivable threshold. The translucency differences were not clinically perceivable for any specimen. After six months, all specimens demonstrated large color changes, whereas the changes in translucency were relatively small. In conclusion, the color of 3D printable dental materials changed with time, and the differences varied with the materials used. On the contrary, the changes in translucency were small. Overall, the materials became darker, more yellowish, and more opaque after six months of water storage.
We incorporated zwitterionic materials into light-curable fluoride varnish (LCFV) in order to inhibit biofilm accumulation and prevent dental caries, and the properties of LCFV with three different zwitterionic materials, namely, 2-methacryloyloxyethyl phosphorylcholine (MPC), carboxybetaine methacrylate (CBMA), and sulfobetaine methacrylate (SBMA) polymers (each at a weight percentage of 3%), were compared; unmodified LCFV without any zwitterionic material was used as a control. Material properties including film thickness and degree of conversion (DC) of each type of LCFV were evaluated. In addition, protein-repellent effects and inhibitory effects on Streptococcus mutans adhesion and saliva-derived biofilm accumulation of LCFV were estimated. Finally, the preventive effect of LCFV on enamel demineralization was assessed in vitro on extracted human teeth specimens stored in S. mutans-containing medium. The film thickness of LCFV significantly decreased with the incorporation of zwitterionic materials compared to the control LCFV, whereas there were no significant differences in the DC among all of the LCFV groups. Furthermore, the amount of adsorbed protein, adherent S. mutans colony-forming unit (CFU) counts, and saliva-derived biofilm thickness and biomass were all significantly lower for LCFV with incorporated zwitterionic materials compared with the control. All LCFV groups including the control showed certain preventive effects against enamel demineralization during a 14-day immersion in the medium with S. mutans and sucrose, and the depth of demineralization was significantly lower in LCFV with zwitterionic materials than in the control. Thus, the incorporation of zwitterionic materials such as MPC, CBMA, and SBMA appears to confer superior antifouling effects to LCFV.
This study aimed to investigate the effects of low-intensity pulsed ultrasound (LIPUS) on replacement root resorption after replantation of avulsed teeth stored in a dry condition in dogs. A total of 73 premolar roots from four male mongrel dogs were intentionally avulsed with forceps and divided into four groups—HN, HL, DN, and DL—according to storage conditions and whether or not they received LIPUS treatment. Thirty-eight roots were kept in Hanks’ Balanced Salt Solution for 30 min (HN and HL groups), whereas the remaining 35 roots were left to dry in the air for an hour (DN and DL groups) prior to replantation. Following replantation, the roots in the HL and DL groups (21 and 18 roots, respectively) received a 20-min daily LIPUS treatment for 2 weeks. The animals were euthanized 4 weeks after the operation. Micro-computed tomography images were acquired for each root and the amount of replacement root resorption was measured three-dimensionally. Histological assessments were also carried out. There was significantly less replacement root resorption for the roots in the DL group compared to the DN group (p < 0.01). Histological findings in the DN group demonstrated evident replacement root resorption, whereas the DL group revealed less severe resorption compared to the DN group. Within the limitations, these results suggest that LIPUS could attenuate the replacement resorption of avulsed teeth stored in a dry condition, thereby improving their prognosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.