Partial discharge (PD) characteristics in air, argon and helium at pressures between 101 kPa (760 Torr) to about 0.27 kPa (2 Torr) under 60 Hz ac energization were studied with various electrode arrangements. Measurements are presented for two representative electrode configurations, (1) needle-plane, with 20 mm spacing and a dielectric barrier, and (2) a twisted pair of insulated conductors. Typical PD currentpulse waveforms are presented. Difficulties in adhering to measurement guidelines defined by the IEC 60270 standard are described, and suggested modifications of the standard procedures are presented for measurement and calibration for low-pressure PD.Index Terms -Partial discharge, experimental setup, partial discharge current-pulse waveform, rise time, partial discharge measurement requirements, guidelines, low pressure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.