Objectives
The purpose of this study was to evaluate the incidence of complications following mandibular reconstruction and to analyse possible contributing factors.
Materials and methods
Clinical data and computed tomography scans of all patients who needed a mandibular reconstruction with a reconstruction plate, free fibula flap (FFF) or iliac crest (DCIA) flap between August 2010 and August 2015 were retrospectively analysed.
Results
One hundred and ninety patients were enrolled, encompassing 77 reconstructions with reconstruction plate, 89 reconstructions with FFF and 24 reconstructions with DCIA flaps. Cutaneous perforation was most frequently detected in the plate subgroup within the early interval and overall (each p = 0.004). Low body mass index (BMI) and total radiation dosage were the most relevant risk factors for the development of analysed complications.
Conclusions
Microvascular bone flaps have overall less skin perforation than reconstruction plates. BMI and expected total radiation dosage have to be respected in choice of reconstructive technique.
Clinical relevance
A treatment algorithm for mandibular reconstructions on the basis of our results is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.