ARTICLE INFO ABSTRACTArticle history:The purpose of this study was to predict the load effect on a damper installed at a nuclear power plant building after a tsunami using a volume of fluid (VOF) numerical analysis method. The wave height was determined by a sine wave function and the tsunami condition was estimated by the wave length. Also, using computational fluid dynamics (CFD), the maximum damper load was set as a boundary condition for the structural analysis that verified how stress and deformation affect the damper. As a result, such simulations estimated the highest stress distribution for a wave length of 350 m with a maximum stress present at the cross point of stiffness installed at the rear end of the damper. The total deformation was approximately 32 mm at the center of damper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.