Most of the seismic data processing procedures are divided into 2-D, 2.5-D, crooked lines or 3-D versions dictated by the differences in the shot and receiver configurations. In this paper, we introduce a tomographic approach that overcomes these geometrical difficulties and provides stable statics solutions from picked first-break times. We also show that the first-break picks contain both the short and the long wavelength surface statics. The solutions are obtained by solving a set of generalized surface-consistent delay-time equations using the method of weighted least squares and conjugate gradient. While iterating, each first-break pick is evaluated to ensure its consistency with the least-squares solution. Based on consistency, we weight the traveltime picks and use them in the next iteration. These weights also serve as an indicator of anomalous picks to the user.We show that long wavelength solutions leave large residual errors in the least-squares solutions. We also use the expected length of the Fresnel zone to differentiate between short and long wavelength static solutions. After removing the influence of long wavelength statics, we apply short wavelength statics to reduce the residual errors further.We demonstrate the validity of our unified method by applying it to actual data examples. The removal of both long and short wavelength statics improves the initial data set that produces a more consistent set of velocities and leaves only the short wavelength residual reflection statics, which are generally less than quarter wavelet period delays. This removes the most probable cause of the leg jump contamination and poor velocity estimates from the residual statics computations, especially from the 3-D data.
This study undertaken by the Central Clinical Drug Evaluation Program includes 682 evaluable patients, undergoing 871 courses of imidazole carboxamide with 39 different types of malignant disease. Toxicity consisted of nausea and vomiting for the first few injections, and hematopoietic depression in a relatively small group. A response of 25.1% was noted in 393 patients with melanoma. At the current dosage the drug seems to be well tolerated and is useful in the treatment of metastatic melanoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.