The Advanced Photon Source (APS) is a thirdgeneration synchrotron light source in its tenth year of operation. The storage ring employs three different types of beam position monitor (BPM) systems to measure and control beam motion. The monopulse radio frequency (rf) BPM is a broadband (10-MHz) system, which is considered to be the backbone of orbit control. The rf BPM system was designed to measure single-turn and multi-turn beam positions.The rf BPMs are presently suffering from an aging data acquisition system. By replacing only the data acquisition we will revitalize this system for another decade and demonstrate a cost-effective approach to improved beam stability, reliability, and enhanced postmortem capabilities. In this paper we present the design of an eight-channel ADC/digitizer VXI board with a sampling rate of 88 MHz (per channel) and 14-bit resolution coupled with a field-programmable gate array and embedded signal processing. We will discuss the upgrade system specifications, design, and prototype test results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.