When completed, the DARHT-II linear induction accelerator (LIA) will produce a 2-kA, 17-MeV electron beam in a 1600-ns flat-top pulse. In initial tests, DARHT-II accelerated beams with current pulse lengths from 500 to 1200 ns full-width at half-maximum (FWHM) with more than 1.2-kA, 12.5-MeV peak current and energy. Experiments have now been done with a 1600-ns pulse length. These pulse lengths are all significantly longer than any other multimegaelectronvolt LIA, and they define a novel regime for high-current beam dynamics, especially with regard to beam stability. Although the initial tests demonstrated insignificant beam-breakup instability (BBU), the pulse length was too short to determine whether ion-hose instability would be present toward the end of a long, 1600-ns pulse. The 1600-ns pulse experiments reported here resolved these issues for the long-pulse DARHT-II LIA.
The second axis of the dual-axis radiography of hydrodynamic testing (DARHT) facility produces up to four radiographs within an interval of 1:6 s. It does this by slicing four micropulses out of a 2-s long electron beam pulse and focusing them onto a bremsstrahlung converter target. The 1.8-kA beam pulse is created by a dispenser cathode diode and accelerated to more than 16 MeV by the unique DARHT Axis-II linear induction accelerator (LIA). Beam motion in the accelerator would be a problem for multipulse flash radiography. High-frequency motion, such as from beam-breakup (BBU) instability, would blur the individual spots. Low-frequency motion, such as produced by pulsed-power variation, would produce spot-to-spot differences. In this article, we describe these sources of beam motion, and the measures we have taken to minimize it. Using the methods discussed, we have reduced beam motion at the accelerator exit to less than 2% of the beam envelope radius for the high-frequency BBU, and less than 1=3 of the envelope radius for the low-frequency sweep.
The DARHT-II linear-induction accelerator has been successfully operated at 1.2-1.3 kA and 12.5-12.7 MeV to demonstrate the production and acceleration of an electron beam. Beam pulse lengths for these experiments were varied from 0.5 s to 1.2 s full-width half-maximum. A low-frequency inductance-capacitance (LC ) oscillation of diode voltage and current resulted in an oscillation of the beam position through interaction with an accidental (static) magnetic dipole in the diode region. There was no growth in the amplitude of this oscillation after propagating more than 44 m through the accelerator, and there was no loss of beam current that could be measured. The results of these initial experiments are presented in this paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.