More than 40 industrial radiography laboratories are operating in Greece using X-ray or gamma-ray sources and more than 250 workers occupationally exposed to ionising radiation in these facilities are monitored on a regular basis. This study presents the evolution of individual doses received by radiographers during the past years. The mean annual dose (MAD) of all workers as well as of exposed workers is estimated, and correlated to the types of laboratories and practices applied. The MAD of the exposed workers in industrial radiography is compared with the doses of workers in other specialties and with the doses of radiographers in other countries. Furthermore, the study attempts to propose dose constraints for the practices in industrial radiography, according to the BSS European directive and the relevant Greek radiation protection legislation. The proposed value was defined as the dose below which the annual doses of 75% of the exposed radiographers are expected to be included.
LiF is a well-known thermoluminescent (TL) material used in individual monitoring, and its fading characteristics have been studied for years. In the present study, the fading characteristics (for a period of 150 d) of various commercial LiF materials with different dopants have been evaluated. The materials used in the study are those used in routine procedures by the Personal Dosimetry Department of Greek Atomic Energy Commission and in particular, LiF:Mg,Ti (MTS-N, TL Poland), LiF:Mg,Cu,P (MCP-N, TL Poland), LiF:Mg,Cu,P (MCP-Ns, thin active layer detector, TL Poland) and LiF:Mg,Cu,P (TLD100H, Harshaw). The study showed that there is a sensitivity loss in signal of up to 20 % for the MTS-N material for a 150-d period in the pre-irradiation fading phase. The MCP-N has a stable behaviour in the pre-irradiation fading phase, but this also depends on the readout system. As far as the post-irradiation fading effect is concerned, a decrease of up to 20 % for the MTS-N material is observed for the same time period. On the other hand, the LiF:Mg,Cu,P material presents a stable behaviour within ± 5 %. These results show that the fading effect is different for each material and should be taken into account when estimating doses from dosemeters that are in use for >2 months.
A quality assurance (QA) and quality control (QC) programme was applied to the personal monitoring department (TLD based) of the Greek Atomic Energy Commission (GAEC). This programme was designed according to the recommendations of international bodies such as the International Organization for Standardization (ISO), the International Electrotechnical Commission (IEC), the International Atomic Energy Agency (IAEA) and the European Commission (CEC). This paper deals with the presentation of the QA/QC programme which includes administrative data and information, technical checking of the equipment, acceptance tests of new equipment and dosemeters, issuing and processing of the dosemeters, dose evaluation, record keeping and reporting, traceability and reproducibility, handling of complaints, internal reviews and external audits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.