Tube bundles can be used as a separation heat exchanger in the “organic” Rankine cycle power plants (ORC), while the hot gas passes over the outer surface, and the working substance in ORC flows inside the tubes. Numerical study of the hydrodynamics and heat transfer of a staggered bundle of drop-shaped tubes at different angle of attack (θ) of the incoming gas flow is carried out using the ANSYS package. The distribution of velocity, pressure, temperature in the studied bundle are obtained and the relation for calculating the average Nusselt number for the stress-strain state of the tubes bundle is proposed. The numerical method of calculation of the elementary, local and average radiation view factors for staggered bundle of drop-shaped tubes is developed using the “crossed-strings method”. The radiation net fluxes in the systems of drop-shaped and circular tubes with the same equivalent diameter are determined.
The paper presents an experimental study of condensation of pure water vapor and water vapor in the presence of octafluoropropane (C3F8) in a vapor-gas mixture (VGM) in a turbulent jet of liquid.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.