The development of solar energy for commercial power generation has been an active area of work for several decades. A limiting design consideration for solar receivers is creep-fatigue because of the high heat fluxes involved and the inherent cyclic nature of solar energy. Design activities and concerns are presented for a recent commercial molten salt receiver application. A critical review of available creep-fatigue data and methods is provided and supplemented with detailed inelastic analysis. Recommendations are made for both design and further material property development that would help to remove conservatism and increase reliability.
Paper published with permission.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.