ObjectivesTo measure changes in air quality during surgery.MethodsOperating room (OR) and hallway air quality was continuously monitored over a 3-month period. Rooftop monitoring was used to control for environmental changes and to account for the infiltration of outdoor air pollutants. Air quality measurements were correlated with operative times and electro-dissection equipment used.ResultsOR air is cooler and drier compared to the adjacent hallway. Volatile organic compounds and other gases are below indoor air exposure limit guidelines. Lasers create greater 2.5 μm particulate matter (PM2.5) mass concentration, and greater fine and coarse particle number than cautery or cold tissue dissection. Cautery produces more ultrafine particles (UFP) than other dissection techniques. OR air has lower particle counts than outdoor environmental air by virtue of air conditioning HEPA filtration.ConclusionCompared to the outside air, operating room air has lower particle counts. Lasers produce higher concentrations of PM2.5 mass and, fine and coarse particle number counts. Cautery produces higher concentrations of UFP number counts than other modalities and warrants consideration of the use of masks with ultrafine particle filtration capacity. Operating room air is consistently cooler with decreased humidity, which may cause airway irritation.
Objectives: To measure changes in air quality during surgery.Methods: Operating room (OR) and hallway air quality was continuously monitored over a 3-month period. Rooftop monitoring was used to control for environmental changes and to account for the infiltration of outdoor air pollutants. Air quality measurements were correlated with operative times and electro-dissection equipment used.Results: OR air is cooler and drier compared to the adjacent hallway. Volatile organic compounds and other gases are below indoor air exposure limit guidelines. Lasers create greater 2.5 μm particulate matter (PM 2.5 ) mass concentration, and greater fine and coarse particle number than cautery or cold tissue dissection. Cautery produces more ultrafine particles (UFP) than other dissection techniques. OR air has lower particle counts than outdoor environmental air by virtue of air conditioning HEPA filtration. Conclusion:Compared to the outside air, operating room air has lower particle counts. Lasers produce higher concentrations of PM 2.5 mass and, fine and coarse particle number counts. Cautery produces higher concentrations of UFP number counts than other modalities and warrants consideration of the use of masks with ultrafine particle filtration capacity. Operating room air is consistently cooler with decreased humidity, which may cause airway irritation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.