Rationale: Transthoracic Doppler echocardiography is recommended for screening for the presence of pulmonary hypertension (PH). However, some recent studies have suggested that Doppler echocardiographic pulmonary artery pressure estimates may frequently be inaccurate. Objectives: Evaluate the accuracy of Doppler echocardiography for estimating pulmonary artery pressure and cardiac output. Methods: We conducted a prospective study on patients with various forms of PH who underwent comprehensive Doppler echocardiography within 1 hour of a clinically indicated right-heart catheterization to compare noninvasive hemodynamic estimates with invasively measured values. Measurements and Main Results: A total of 65 patients completed the study protocol. Using Bland-Altman analytic methods, the bias for the echocardiographic estimates of the pulmonary artery systolic pressure was 20.6 mm Hg with 95% limits of agreement ranging from 138.8 to 240.0 mm Hg. Doppler echocardiography was inaccurate (defined as being greater than 610 mm Hg of the invasive measurement) in 48% of cases. Overestimation and underestimation of pulmonary artery systolic pressure by Doppler echocardiography occurred with a similar frequency (16 vs. 15 instances, respectively). The magnitude of pressure underestimation was greater than overestimation (230 6 16 vs. 119 6 11 mm Hg; P 5 0.03); underestimates by Doppler also led more often to misclassification of the severity of the PH. For cardiac output measurement, the bias was 20.1 L/min with 95% limits of agreement ranging from 12.2 to 22.4 L/min. Conclusions: Doppler echocardiography may frequently be inaccurate in estimating pulmonary artery pressure and cardiac output in patients being evaluated for PH.Keywords: echocardiography; pulmonary hypertension; pulmonary systolic pressure; cardiac output; accuracy Pulmonary hypertension (PH), a syndrome characterized by increased pulmonary vascular resistance and remodeling, is associated with significant morbidity and mortality, which are directly related to cardiac function (1). Although the definitive diagnosis of PH is currently established through right-heart catheterization, accurate noninvasive assessment of pulmonary arterial pressure and cardiac output (CO) is desirable both for diagnostic purposes and to assess response to therapy.Transthoracic Doppler echocardiography (DE) is recommended as the initial noninvasive modality in the screening and evaluation of PH (2). Echocardiography can be used to evaluate right-sided chamber size and function and the presence of pericardial effusion, which are known to impact survival (3-5). Frequently, DE is used to estimate the right ventricular systolic pressure by estimating the pressure gradient between the right ventricle and the right atrium using the modified Bernoulli equation, 4v 2 , where v equals the velocity of the tricuspid regurgitant jet. An estimated right atrial pressure is added to this number to approximate the right ventricular systolic pressure, which equals the pulmonary artery systolic pres...
TAPSE powerfully reflects RV function and prognosis in PAH.
BackgroundLeft atrium (LA) strain, volume and function are important markers of cardiovascular disease and myocardial impairment. We aimed to assess the accuracy of LA biplane volume and function measured by Multimodality Tissue Tracking (MTT). Also we assessed the inter-study reproducibility for cardiovascular magnetic resonance (CMR) derived LA volume and function parameters.MethodsThirty subjects (mean age: 71.3 ± 8.7, 87 % male) including twenty subjects with cardiovascular events and ten healthy subjects, with CMR were evaluated in the Multi-Ethnic Study of Atherosclerosis (MESA). LA volumes were computed by the modified biplane method from 2- and 4-chamber projections and the Simpson’s method from short-axis slices using both methods - manual and semi-automated delineation using MTT. LA total, active and passive ejection fractions were calculated. Pearson’s correlation and Bland-Altman analysis were used to compare the measurements. In a second sample of 25 subjects (age: 65.7 ± 7.1, 72 % males) inter study, intra and inter reader reliability analysis was performed. The intra-class correlation coefficient (ICC) was evaluated.ResultsLeft atrial MTT structural and functional parameters were not different from manual delineation, yet image analysis was only half as time consuming on average with MTT. Maximal volume MTT was not different between the Simpson’s and Biplane methods, functional parameters, however were different. MTT allowed us to measure multiple LA parameters with good-excellent (ICC; 0.88– 0.98, p < 0.001) intra-and inter reader reproducibility and fair-good (ICC; 0.44–0.82, p < 0.05–0.001) inter study reproducibility.ConclusionsMTT derived LA biplane volume and function is accurate and reproducible and is suited for use in longitudinal studies.
Inter-study reproducibility of all aortic variables was acceptable. Intra- and inter-observer reproducibility of all aortic variables was excellent. MRI can provide a repeatable method of measuring aortic structural and functional parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.