A formal, structured handover process for pediatric patients transitioning to the intensive care unit after cardiac surgery can reduce medical errors that occur during the admission process and improve teamwork among caregivers.
Study Objective: Determine near-optimal dose, safety, and efficacy of nerindocianine in pelvic ureter detection with near-infrared fluorescence imaging in women undergoing minimally invasive pelvic surgery with 3 Food and Drug Administration−cleared imaging systems. Design: Open label, phase 1/2a study. Setting: University of Alabama at Birmingham. Patients: Forty-one female subjects undergoing minimally invasive gynecologic surgery. Interventions: Subjects received a single dose of nerindocianine sodium, starting at 0.06-mg/kg body weight and increased/ decreased until the near-optimal dose was determined (part A). Examine the degree of concordance between endoscopic and robotic devices (part B).
Measurements and Main Results:In part A, composite scores were collected every 10 minutes for 30 minutes and then every 15 minutes through 90 minutes using a scale measuring the anatomy/laterality of ureter visualization. In part B (paired imaging system efficacy), 2 cohorts of 8 subjects each received the near-optimal dose. Composite scores for visualization of the ureter were collected at 10 and 30 minutes postinfusion with the Firefly Imaging System and either the PINPOINT or 1588 AIM endoscope. Composite scores were compared to examine the degree of concordance between devices. Part A comprised 25 total subjects enrolled in dosing groups 1, 2, and 3 (0.06-, 0.12-, and 0.045-mg/kg, respectively). Median time to first ureter visualization was 10 minutes (all groups). The nerindocianine 0.06-mg/kg and 0.12-mg/kg groups had longer length of time of visualization than the 0.045-mg/kg group, resulting in the selection of 0.06 mg/kg as the near-optimal dose. Part B enrolled 16 total subjects in 2 groups dosed at 0.06 mg/kg. Efficacy analysis showed no statistically significant difference in composite scores with Firefly versus PINPOINT or 1588 AIM. Conclusion: Nerindocianine was well tolerated with visualization of the ureter demonstrated in 88.9% of the subjects through 90 minutes postdosing. No meaningful visualization differences were observed among the Food and Drug Administration−cleared surgical imaging systems used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.