IntroductionThis study compares different parameters derived from electrical impedance tomography (EIT) data to define ‘best’ positive end-expiratory pressure (PEEP) during a decremental PEEP trial in mechanically-ventilated patients. ‘Best’ PEEP is regarded as minimal lung collapse and overdistention in order to prevent ventilator-induced lung injury.MethodsA decremental PEEP trial (from 15 to 0 cm H2O PEEP in 4 steps) was performed in 12 post-cardiac surgery patients on the ICU. At each PEEP step, EIT measurements were performed and from this data the following were calculated: tidal impedance variation (TIV), regional compliance, ventilation surface area (VSA), center of ventilation (COV), regional ventilation delay (RVD index), global inhomogeneity (GI index), and intratidal gas distribution. From the latter parameter we developed the ITV index as a new homogeneity parameter. The EIT parameters were compared with dynamic compliance and the PaO2/FiO2 ratio.ResultsDynamic compliance and the PaO2/FiO2 ratio had the highest value at 10 and 15 cm H2O PEEP, respectively. TIV, regional compliance and VSA had a maximum value at 5 cm H2O PEEP for the non-dependent lung region and a maximal value at 15 cm H2O PEEP for the dependent lung region. GI index showed the lowest value at 10 cm H2O PEEP, whereas for COV and the RVD index this was at 15 cm H2O PEEP. The intratidal gas distribution showed an equal contribution of both lung regions at a specific PEEP level in each patient.ConclusionIn post-cardiac surgery patients, the ITV index was comparable with dynamic compliance to indicate ‘best’ PEEP. The ITV index can visualize the PEEP level at which ventilation of the non-dependent region is diminished, indicating overdistention. Additional studies should test whether application of this specific PEEP level leads to better outcome and also confirm these results in patients with acute respiratory distress syndrome.
The CERAB technique is a safe and feasible technique for the treatment of extensive AIOD with good 3-year results regarding patency and clinical improvement.
Although nitinol self-expandable stents have a high stent conformation, the lowest radial mismatch was found in the CERAB (1) configuration, supporting the hypothesis that the CERAB configuration is the most anatomical and physiological reconstruction of the aortic bifurcation. Within the CERAB configuration, the two limbs are ideally positioned inside the tapering portion of the cuff, minimizing mismatch.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.