The purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation.
Aim of Study:With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision.Materials and Methods:Case report and literature review.Results:This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up.Conclusion:We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized.
Objectives:We aimed to evaluate the development of posterior capsular opacification (PCO) in preschool- and school-age children with cataract who underwent cataract surgery without posterior capsulotomy and anterior vitrectomy.Materials and Methods:The records of 30 eyes of 21 patients who underwent pediatric cataract surgery and intraocular lens (IOL) implantation were retrospectively reviewed. Patients’ age, PCO status and duration, need for neodymium-doped yttrium aluminium garnet (Nd:YAG) laser treatment based on coverage of visual axis, and follow-up period were recorded.Results:The mean age of the patients was 7.6±2.83 (4-12) years. Unilateral cataract surgery and IOL implantation were performed in 12 patients (57.14%) and bilateral cataract surgery and IOL implantation were performed in nine patients (42.86%). Average follow-up time was 17.7±22.67 (3-83) months. PCO developed in 21 eyes (70%) and covered the visual axis in 15 eyes (50%), which therefore required Nd:YAG laser posterior capsulotomy. The mean duration of postoperative PCO development was 8.91±18.7 months (1 week-71 months).Conclusion:We believe that with adequately experienced surgeons, performing both cataract surgery and posterior capsulotomy with anterior vitrectomy in the same session is appropriate for selected preschool- and school-age children with cataract.
The results of this study imply the protective effect of diabetes over glaucomatous optic nerve damage in POAG patients. However, larger and controlled studies are warranted to confirm those findings.
A new intrascleral fixation technique for a standard 3-piece posterior chamber intraocular lens (PC IOL) using a simple guide is described. To secure the haptics, 27-gauge scleral tunnels are created. Both haptics are secured extraocularly. The leading haptic of the PC IOL placed in the cartridge is released partly and introduced into the lumen of the guide. The PC IOL is inserted into the eye, and the leading haptic is externalized by pulling the guide gently through the 27-gauge sclerotomy site. The trailing haptic is externalized using the same procedure. This technique facilitates achieving minimally invasive sutureless intrascleral PC IOL fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.