Among patients with colon polyps, 2.9% were found to have SSAs. Most of the SSAs were located in the right side and were safely managed by colonoscopy.
BackgroundSafe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure.AimTo better understand the use and value of ETM during colonoscopy by using a device that allows real-time imaging of the colonoscope insertion shaft.MethodsThe use of ETM during colonoscopy and their success was recorded. Experienced colonoscopists and endoscopy assistants used a commercially available electromagnetic (EM) transmitter and a special adult variable stiffness instrument with 12 embedded sensors to examine 46 patients. In 5 of these a special EM probe passed through the instrument channel of a standard pediatric variable stiffness colonoscope was used instead of the EM colonoscope.ResultsThirty-nine men and 7 women with a mean age of 64 years (range 33–90) were studied. The cecum was intubated in 93.5% (43/46). The mean time to reach the cecum was 10.6 minutes (range 3–25). ETM were used a total of 174 times in 41 of the patients to assist with cecal intubation. When ETM were required to reach the cecum, and the cecum was intubated, an average of 3.82 ETM/patient was used. While ETM were used most often when the tip of the colonoscope was in the left side of the colon (rectum 5.0%, sigmoid colon 20.7%, descending colon 5.0%, and splenic flexure 11.6%), when the instrument was in the transverse colon (14.8%), hepatic flexure (20.7%) and ascending colon (19.8%) the use of ETM was also required. When the colonoscope tip was in the transverse colon, hepatic flexure and ascending colon, ETM success rates were less (61.1%, 52.0%, and 41.7% respectively) compared to the left colon success rates (rectum 83.3%, sigmoid colon 84.0%, descending colon 100%, and splenic flexure 85.7%).ConclusionThe EM colonoscope allows imaging of the insertion shaft without fluoroscopy and is a useful device for evaluating the efficacy of ETM. ETM are important tools of the colonoscopist and are used most often in the left colon where they are most effective.
Necrotizing fasciitis is a rare and potentially fatal infection, with mortality of up to 30%. This case report describes a patient recovering from a laryngectomy for laryngeal squamous cell cancer who developed nosocomial necrotizing fasciitis of the lower extremity due to Serratia marcescens . Only eight cases of necrotizing fasciitis exclusive to the lower extremity due to S marcescens have been previously reported. Patients with S marcescens necrotizing fasciitis of the lower extremity often have multiple comorbidities, are frequently immunosuppressed, and have a strikingly high mortality rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.