A parameter that allows an evaluation of power quality transmitted, or distributed, between energy source and the final user is electric system power factor. Among other aspects, a bigger power factor, close to unit value, relieves operational conditions of lines and cables, besides, it improves feeder's voltage behavior. Due to load variation along the day, the dynamic compensation of power factor allows maintaining this parameter close to the ideal. This paper brings a study about a reactive dynamic compensator based on the voltage control in a capacitive element, varying the reactive energy in accordance with the system demand, everything from the energy efficiency point of view. In distribution systems, the losses due to this variable compensation can be lower than in other compensation methods and also the voltage presents a better behavior, justifying its application.
Resumo-O conceito de capacidade de hospedagem (CH) está se tornando mais difundido, já que é uma abordagem abrangente que permite entender os impactos da geração distribuída nas redes. Vários métodos de cálculo da CH foram desenvolvidos nos últimos anos e são classificados em determinísticos, estocásticos e séries temporais, cada qual com os seus respectivos prós e contras. Dentro desse contexto, neste artigo é proposta uma metodologia híbrida que combina os métodos determinísticos e de séries temporais, no cálculo da CH de um alimentador real, situado em Poços de Caldas, MG, da concessionária DMED. O referido alimentador foi modelado e analisado levando-se em consideração variações de cargas e de potência injetada por fontes GD nas diferentes barras que compõem o sistema. Por fim, os resultados alcançados demonstram a eficácia da metodologia proposta.
Inclui bibliografia. Ficha Catalográfica Online do Sistema de Bibliotecas da UFU com dados informados pelo(a) próprio(a) autor(a). Bibliotecários responsáveis pela estrutura de acordo com o AACR2: Gizele Cristine Nunes do Couto -CRB6/2091 v Dedico este trabalho à Carolina, pelo apoio, carinho e compreensão (além do espantoso costume de aparecer nas dedicatórias durante toda minha vida acadêmica). vi Ao professor Luiz Carlos Gomes de Freitas pela orientação deste trabalho. Ao professor Sérgio Ferreira de Paula Silva pela disponibilidade e conselhos. Aos colegas do DME pela atenção, paciência e dedicação essenciais para execução deste trabalho. Ao IFSULDEMINAS e a ANEEL pelo financiamento deste projeto. À minha família, pelo incentivo e compreensão. vii O conceito de capacidade de hospedagem (CH) está se tornando mais difundido, já que é uma abordagem abrangente que permite entender os impactos da geração distribuída nas redes. Vários métodos de cálculo da CH foram desenvolvidos nos últimos anos e são classificados basicamente em determinísticos, estocásticos e séries temporais, cada qual com os seus respectivos prós e contras. Dentro desse contexto, neste trabalho é proposta uma metodologia híbrida que combina os métodos determinísticos e de séries temporais, no cálculo da CH de um alimentador real, situado em Poços de Caldas, MG, da concessionária DMED. O referido alimentador foi modelado e analisado levando-se em consideração variações de cargas e de potência injetada por fontes de geração distribuída nas diferentes barras que compõem o sistema. Por fim, os resultados alcançados demonstram a eficácia da metodologia proposta e coerência com os métodos tradicionais. Palavras-Chave: Geração distribuída; capacidade de hospedagem; limite de sustentabilidade; penetração fotovoltaica; redes de distribuição; fluxo de carga. viiiThe concept of hosting capacity (HC) is becoming more widespread, as it is an approach of ample scope and brings with it an understanding into the impacts of distributed generation on grids. Various methods for calculating HC have been developed over recent years and are classified as deterministic, stochastic and time series, each with its respective pros and cons. Within this context, the author of the present thesis proposes a hybrid methodology that combines the deterministic and time series methods into the HC calculation of a real feeder, located in , MG, from the energy utility DMED. The feeder referred to herein was modelled and analyzed, while taking into consideration variations in loads and power injected by distributed generation (DG) sources on different buses that make up the system. Finally, the results obtained demonstrate the efficiency of the proposed method.
The main methods employed for Hosting Capacity (HC) calculations are basically classified into deterministic, stochastic and time series. In this scenario, the authors herein propose a hybrid methodology, which shows efficiency and ease of implementation. Besides the method presented, it is also calculated a hosting capacity of a real feeder which was modeled and analyzed taking into consideration variations in load and power injected by distributed generation sources. The proposed hybrid method deploys just one time series with the feeder power demand data, which are easily obtained from the feeder’s origin substation. Low voltage loads were modeled by the ratio between their maximum demands and the feeder maximum demand, making easier to start up the grid model implementation. Hence, the advantages of the proposed methodology can be summarized in: (a) easy to obtain the input parameters; (b) agility in implementing the study; (c) higher processing speed and (d) results consistent with the time series method. Finally, in view of the advantages and obtained results, the proposed hybrid methodology shows itself as a promising and attractive tool for the studies of hosting capacity by the utilities.
Ao professor Antônio Carlos Delaiba pelo incentivo, motivação e orientação deste trabalho. Aos professor. Sérgio Ferreira de Paula Silva pela orientação, dedicação e tempo essenciais para execução deste trabalho À minha família, pelo incentivo e compreensão. ResumoO desenvolvimento de uma teoria sobre o comportamento da potência elétrica na presença de harmônicas é um tema abrangente e complexo. As primeiras pesquisas na área datam de 1927 e 1932 e, até o presente momento, não há um consenso.A importância deste tema está em compreender o funcionamento da transferência de energia em um circuito elétrico uma vez que as definições clássicas de potência elétrica, apresentadas nos livros-texto do ciclo básico de engenharia, não retratam de forma fidedigna as interações dos fluxos de energia em redes cujos sinais estão distorcidos, situação típica dos sistemas elétricos atuais.Neste contexto, a maior controvérsia está na qualificação e quantificação da Potência Reativa. Assim, esta dissertação visa contribuir aos estudos em regimes não senoidais com enfoque nas definições de potência elétrica, tecendo comentários sobre a potência ativa e dando especial atenção a potência reativa e suas implicações.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.