A microfluidic device based on an inductive Coulter counting principle to detect metal wear particles in lubrication oil is presented. The device detects the passage of ferrous and nonferrous particles by monitoring the inductance change of an embedded coil. The device was tested using iron and copper particles ranging in size from 50 to 125 lm. The testing results have demonstrated that the device is capable of detecting and distinguishing ferrous and nonferrous metal particles in lubrication oil; such particles can be indicative of potential machine faults in rotating and reciprocating machinery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.