Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to Ö NORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density.The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. r
Several methods and procedures for the determination of particle density of pellets and briquettes were tested and evaluated. Round robin trials were organized involving five European laboratories, which measured the particle densities of 15 pellet and five briquette types. The test included stereometric methods, methods based on liquid displacement (hydrostatic and buoyancy) applying different procedures and one method based on solid displacement.From the results for both pellets and briquettes, it became clear that the application of a method based on either liquid or solid displacement (only tested on pellet samples) leads to an improved reproducibility compared to a stereometric method. For both, pellets and briquettes, the variability of measurements strongly depends on the fuel type itself.For briquettes, the three methods tested based on liquid displacement lead to similar results. A coating of the samples with paraffin did not improve the repeatability and the reproducibility.Determinations with pellets proved to be most reliable when the buoyancy method was applied using a wetting agent to reduce surface tensions without sample coating. This method gave the best values for repeatability and reproducibility, thus less replications are required to reach a given accuracy level. For wood pellets, the method based on solid displacement gave better values of repeatability, however, this instrument was tested at only one laboratory. r
Methods for size classification of wood chips were analysed in an international round robin using 13 conventional wood chip samples and two specially prepared standard samples, one from wood chips and one from hog fuel. The true size distribution of these two samples (according to length, width and height) had been determined stereometrically (reference method) using a digital calliper gauge and by weighing each of the about 7000 wood particles per sample. Five different horizontal and three rotary screening devices were tested using five different screen hole diameters (3.15, 8, 16, 45, 63 mm, round holes). These systems are compared to a commercially available continuously measuring image analysis equipment.The results show that among the devices of a measuring principle-horizontal and rotary screening-the results are quite comparable, while there is a severe incompatibility when distributions are determined by different measuring principles. Highest conformity with the reference values is given for measurements with an image analysis system, whereas for all machines with horizontal screens the median value of the size distribution only reached between one-third to half of the reference median value for the particle length distribution. These deviations can be attributed to a higher particle misplacement, which is particularly found in the larger fractions. Such differences decrease when the particle's shape is more roundish (i.e. sphericity closer to one). The median values of length distributions from screenings with a rotary classifier are between the measurements from an image analysis and horizontal screening devices. r
Le siège du CEPMMT à Reading (Royaume-Uni).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.