Background: Transcatheter Aortic Valve Replacements (TAVR) has become widespread throughout the world. To date there are no echocardiographic study of TAVR patients from Southeast Asia (SEA). We sought to evaluate 1) changes in echocardiographic and strain values pre and post TAVR 2) relationship between aortic stenosis (AS) severity and strain values, 3) left ventricle geometry in severe AS 4) relationship of flow rate to dimensionless index (DVI) and acceleration time (AT) and 5) effect of strains on outcome. Methods: Retrospective study of 112 TAVR patients in our center from 2009 to 2020. The echocardiographic and strain images pre (within 1 months), post (day after) and 6 months post TAVR were analyzed by expert echocardiographer. Results: The ejection fraction (EF) increased at 6 months (53.02 ± 12.12% to 56.35 ± 9.00%) (p=0.044). Interventricular septal thickness in diastole (IVSd) decreased (1.27 ± 0.21cm to 1.21 ± 0.23cm) (p=0.038) and left ventricle internal dimension in diastole (LVIDd) decreased from 4.77 ± 0.64cm to 4.49 ± 0.65cm (p = 0.001). No changes in stroke volume index (SVI pre vs 6 months p =0.187), but the flow rate increases (217.80 ± 57.61mls/s to 251.94 ± 69.59mls/s, p<0.001). Global Longitudinal Strain (GLS) improved from -11.44 ± 4.23% to -13.94 ± 3.72% (p <0.001), Left Atrial Reservoir strain (Lar-S) increased from 17.44 ± 9.16% to 19.60 ± 8.77% (p=0.033). 8 patients (7.5%) had IVSd < 1.0cm, and 4 patients (3.7%) had normal left ventricle (LV) geometry. There was linear relationship between IVSd and mean PG (r=0.208, p=0.031), between GLS to aortic valve area (AVA) and aortic valve area index (AVAi) (r = – 0.305, p=0.001 and r= – 0.316, p = 0.001). There was also relationship between AT (r=-0.20, p=0.04) and DVI (r=0.35, p< 0.001) with flow rate. Patients who died late (after 6 months) had lower GLS at 6 months. (Alive; -13.94 ± 3.72% vs Died; -12.43 ± 4.19%, p= 0.001) Conclusion: At 6 months TAVR cause reverse remodeling of the LV with reduction in IVSd, LVIDd and improvement in GLS and LAr-S. There is linear relationship between GLS and AVA and between IVSd and AVA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.