BackgroundThe introduction of the frozen elephant trunk (FET) technique for total arch replacement (TAR) has revolutionized the field of aortivascular surgery by allowing hybrid repair of complex aortic pathologies in a single step through combining an open surgical approach with an endovascular one. FET has been associated with favorable aortic remodeling, however, its is also associated with development of distal stent graft induced new entry (dSINE) tears postoperatively. The rate of aortic remodeling and the incidence of dSINE have been linked together, in addition, there seems to be a relationship between these two variables and FET insetion length as well as graft size.AimsThe scope of this review is to highlight the rate of aortic remodeling as well the incidence of dSINE associated with different FET devices available commercially. This review also aimed to investigate the relationship between aortic remodeling, dSINE, FET insertion length and FET graft size.MethodsWe conducted a comprehensive literature search using multiple electronic databases including PubMed, Ovid, Scopus and Embase in order to collate all research evidence on the above mentioned variables.ResultsThoraflex™ Hybrid Plexus seems to yield optimum aortic remodeling by promoting maximum false thrombosis as well true lumen expansion. Thoraflex Hybrid™ is also associated with the lowest incidence of dSINE post-FET relative to the other FET devices on the market. Aortic remodeling and dSINE do influence each other and are both linked with FET graft length and size.ConclusionThe FET technique for TAR shows excellent aortic remodeling but is associated with a considerable risk of dSINE development. However, Thoraflex™ Hybrid has demonstrated itself to be the superior FET device on the aortic arch prostheses market. Since aortic remodeling, dSINE, FET insertion length and stent graft size are all interconnect, the choice of FET device length and size must be made with great care for optimum results.
Objective This systematic review aims to identify predictors of outcomes of mesenteric ischemia in patients following cardiac surgery. Methods A comprehensive literature search was done on EMBASE, PubMed, Ovid MEDLINE, and SCOPUS using keywords relating to bowel ischemia and cardiac surgery. Database search results were screened by at least two authors and 32 articles were selected for inclusion in this review. Results Data on 1907 patients were analyzed. The mean age was 70.0 ± 2.99 years and the prevalence of bowel ischemia was 1.74%. Advanced age was a significant risk factor. 63.16% of patients reported were men, and 58.4% of patients died in hospital. There was heterogeneity in the reported significance of the following preoperative risk factors: hypertension, smoking status, type 2 diabetes mellitus, end‐stage renal disease, preoperative left ventricular ejection fraction <35%. Cardiopulmonary bypass (CPB) time, preoperative/operative intra‐aortic balloon pump (IABP) support, and inotrope usage were significantly associated with the development of mesenteric ischemia; however, other intraoperative factors including the type of cardiac surgery and duration of aortic cross‐clamping had varying levels of reported significance. There were discrepancies in the reported significance of leukocytosis and metabolic acidosis (pH <7.3) as postoperative markers. Postoperative vasopressor use, prolonged ventilation time, and elevation in lactate, transaminases, creatinine, and intestinal fatty acid‐binding protein (IFABP) levels were found to be strongly associated with bowel ischemia. Conclusion This systematic review found the strongest associations of mesenteric ischemia postcardiac surgery to be advanced age, CPB time, rise in lactate, transaminases, creatinine, and IFABP. IABP support, vasopressor, and inotrope use as well as prolonged ventilation were strongly linked too.
IntroductionKinking of the Frozen Elephant Trunk (FET) stent graft is one of the most devastating complications of the FET procedure. It can present post-operatively with reduced arterial pressures in the lower limbs and intermittent claudication. However, it can also be visualized intra-operatively by the surgeons. Unresolved kinking of the stent graft can result in intraluminal thrombus formation and subsequent multi-organ septic emboli.AimsThe main scope of this review is to collate, summarize and present all the evidence in the literature on kinking of FET stent grafts.MethodsWe carried out a comprehensive literature search on multiple electronic databases including PubMed, EMBASE, Ovid, and Scopus to collate all research evidence on the incidence, mechanism, and management of FET graft kinking.ResultsIncidence of kinking is variable, ranging from 0% to 8% in the literature, with varying rates associated with each stent graft type. The Thoraflex HybridTM prosthesis seemed to be the most commonly used and superior graft, and out of all the 15 cases of kinking reported in the literature, 5 (33.3%) were associated with just the Frozenix graft which had the highest incidence. There are multiple theories regarding the mechanism of kinking, including the direction of blood flow, the length of the stent grafts used, and the position of the prosthesis in relation to the flexure of the aorta. Multiple reparative management techniques have been suggested in the literature and include total endovascular repair, open repair, balloon dilatation, and deploying a second stent graft.ConclusionGraft kinking is one of the most critical complications of the FET technique. Its life-threatening sequelae warrant appropriate follow-up of these patients post-operatively, in addition to time management if kinking is suspected. Given the limited evidence in the literature, future studies should incorporate graft kinking into their outcomes reporting.
Background: Type A aortic dissection (TAAD) involves a tear in the intimal layer of the thoracic aorta proximal to the left subclavian artery, and hence, carries a high risk of mortality and morbidity and requires urgent intervention. This dissection can extend into the main coronary arteries. Coronary artery involvement in TAAD can either be due to retrograde extension of the dissection flap into the coronaries or compression and/or blockage of these vessels by the dissection flap, possibly causing myocardial ischemia. Due to the emergent nature of TAAD, coronary involvement is often missed during diagnosis, thereby delaying the required intervention. Aims:The main scope of this review is to summarize the literature on the incidence, mechanism, diagnosis, and treatment of coronary artery involvement in TAAD.Methods: A comprehensive literature search was performed using multiple electronic databases, including PubMed, Ovid, Scopus and Embase, to identify and extract relevant studies.Results: Incidence of coronary artery involvement in TAAD was seldom reported in the literature, however, some studies have described patients diagnosed either preoperatively, intraoperatively following aortic clamping, or even during autopsy.Among the few studies that reported on this matter, the treatment choice for coronary involvement in TAAD was varied, with the majority revascularizing the coronary arteries using coronary artery bypass grafting or direct local repair of the vessels. It is well-established that coronary artery involvement in TAAD adds to the already high mortality and morbidity associated with this disease. Lastly, the right main coronary artery was often more implicated than the left. Conclusion:This review reiterates the significance of an accurate diagnosis and timely and effective interventions to improve prognosis. Finally, further large cohort studies and longer trials are needed to reach a definitive consensus on the best approach for coronary involvement in TAAD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.