A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.
The controversy over the use of nonpulsatile versus pulsatile pumps for maintenance of normal organ function during ex vivo perfusion has continued for many years, but resolution has been limited by lack of a congruent mathematical definition of pulsatility. We hypothesized that the waveform frequency and amplitude, as well as the underlying mean distending pressure are all key parameters controlling vascular function. Using discrete Fourier Analysis, our data demonstrate the complexity of the pulmonary arterial pressure waveform in vivo and the failure of commonly available perfusion pumps to mimic in vivo dynamics. In addition, our data show that the key harmonic signatures are intrinsic to the perfusion pumps, are similar for flow and pressure waveforms, and are unchanged by characteristics of the downstream perfusion circuit or perfusate viscosity.
The dynamic characteristics of catheter-transducer systems using rigid tubes with compliance lumped in the transducer and oscillatory flow of fluid in rigid tubes were analyzed. A digital computer model based on one dimensional laminar oscillatory flow was developed and verified by exact solution of the Navier-Stokes Equation. Experimental results indicated that the damping ratio and resistance is much higher at higher frequencies of oscillation than predicted by the one dimensional model. An empirical correction factor was developed and incorporated into the computer model to correct the model to the experimental data. Amplitude of oscillation was found to have no effect on damping ratio so it was concluded that the increased damping ratio and resistance at higher frequencies was not due to turbulence but to two dimensional flow effects. Graphs and equations were developed to calculate damping ratio and undamped natural frequency of a catheter-transducer system from system parameters. Graphs and equations were also developed to calculate resistance and inertance for oscillatory flow in rigid tubes from system parameters and frequency of oscillation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.