In this large unselected cohort, a high prevalence of symptomatic neurocognitive disorders was mainly related to its traditional determinants and associated with gray matter atrophy at early stages of the disease.
One of two adults with controlled HIV infection had poor lower limb muscle performance, which might put this population at risk of falls and fracture. The 5STS test is a simple test that should be recommended to assess muscular performance in HIV care.
Post-operative instrumented spine infection (PISI) is an infrequent complication.Diagnosis of spinal implant infection can be difficult, especially in case of chronic infection.Methods: This retrospective study attempts to evaluate the diagnostic performance of [ 18 F]fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in PISI. Imagings were performed between April 2010 and June 2018 among patients referred for suspected chronic spinal implant infection. PET/CT were performed more than 12 weeks after surgery. PET/CT images were re-interpreted independently by two nuclear medicine physicians without knowledge of the patient's conditions. PET/CT data were analyzed both visually and semi-quantitatively (SUV max ). MRI results were collected from medical records. The final diagnosis of infection was based on bacteriological cultures or a twelve-month follow-up.Results: Forty-nine PET/CT were performed in 44 patients (22 women, median age 65.0 years). Twenty-two patients had a diagnosis of infection during follow-up. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for PET/CT were 86.4%, 81.5%, 79.2%, and 88.0%. Sensitivity, specificity, PPV and NPV were 66.7%, 75.0%, 66.0%, 75.0% respectively for MRI and 50.0%, 92.6%, 84.6% and 69.4% for serum C-reactive protein (CRP). Although these values were higher for PET/CT than for MRI or CRP, the differences were not statistically significant. In this setting, false positives with PET/CT can be observed in case of previous spine infection or adjacent segments disc disease. False negatives can result of extensive instrumented arthrodesis or infection with low virulence bacteria.
Conclusion:PET/CT is useful for the diagnosis of PISI. These results should be evaluated in further prospective study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.