The aim of this investigation was to improve power performance of Savonius hydraulic turbine utilizing small stream for electric generation. An attempt was made to increase the power coefficient of runner by the use of flat shield plate placed upstream of the runner. The difference of the power coefficient is discussed in relation to clearance between the runner and the bottom wall and the rotation direction of the runner. The flow field around the runner was also examined visually to clarify influences of setting conditions on the power performance. From this study it was found that the power coefficient is achieved for 0.47 by only using a flat shield plate, the increase is up to 80% over the runner without the plate. Moreover, it is the proper condition that clearance ratio is 0.73 in this study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.