This work evaluates the radiation hazard indices from some selected mining sites in Nasarawa West, using Sodium Iodide Thallium Gamma Spectrometry. Raeq ranged from 100.39-197.40 Bq/Kg with a mean 161.44 Bq/Kg, which is lower than the average of 370 Bq/Kg. The GADR ranged from 44.85 nGy/hr-90.71 nGy/hr with the mean 73.68 nGy/hr. which is also below the average of 89 nGy/hr for soil. The AGED ranged from 315.77 mSv/yr-640.91 mSv/yr with the mean 519.19. Which is above the threshold value of 300 mSv/yr. ACI ranged from 0.73-1.45 with the mean value 1.18 which is above the standard of unity. The AEDE (outdoor) ranges from 0.055 mSv/yr-0.111 mSv/yr with the mean 0.090 mSv/yr which is above the 0.07 mSv/yr standard permissible limit. The AEDE (indoor) ranged from 0.220 mSv/yr-0.445 mSv/yr, with the mean value 0.361mSv/yr. This is below the 0.45 mSv/yr threshold. The ELCR ranged from 00.770-1.558 with the mean value 1.265 and from 0.193-0.389 with the mean value 0.317 for outdoor and indoor respectively, which exceed the 0.29 X 10-3 threshold limit. The External and Internal Hazard indices ranges from 0.271-0.533 and 0.289-0.675 as well as mean values 0.435 and 0.512 respectively, which are below the threshold. Therefore, there may be serious radiological effects to the populace.
This study has established local diagnostic reference levels (LDRLs). Dose report and scan parameters for the head was assessed during seven months at the three study centres. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average-sized patients for each facility to establish a local Diagnostic reference level (LDRLs) and radiation dose optimization Data was collected using a purposive sampling technique, from 131 adult patients weighing 70±3kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for this study. The collected data were analyzed using SPPSS version (20) statistical software. Third quartile values of the estimated LDRLs for CTDIw and DLP was determined as 49.8 mGy and 9639 mGy. The mean CTDIw obtained are lower to the reported data from the European Commission of 60mGy. The mean DLP are comparably lower than all the reported value from the European commission of 1050 mGy. Therefore, CT dose optimization is recommended.
This study has established local diagnostic reference levels (LDRLs). Dose report and scan parameters for abdomen was assessed during the period of seven months at the three study centres. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average sized patients for each facility to established a local Diagnostic reference level (LDRLs) and radiation dose optimization Data was collected using a purposive sampling technique, from 131 adult patients weighing 70±3 kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for this study. Third quartile values of the estimated LDRLs for CTDIw and DLP was determined as 12.7 mGy and 560 mGy*cm. The mean CTDIw obtained are lower to the reported data from the European Commission of 35 mGy. The mean DLP are comparably lower than all the reported value from the European commission of 780 mGy/cm. Therefore, there is no any clinical implication and hence CT dose optimization is recommended.
The term "computed tomography" (CT) is often used to refer to X-ray CT, because it is the most commonly known form. But, many other types of CT exist, such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). This study was carried out in the north central part of Nigeria which includes Abuja and Keffi (Nasarawa State). This study has established local diagnostic reference levels (LDRLs). Dose report and scan parameters for chest was assessed during the period (January – July, 2016) of seven months at the three study centres (A, B and C in which two are located in Abuja and the other one (C) located in Keffi. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average sized patients for each facility to established a local Diagnostic reference level (LDRLs) and radiation dose optimization Data was collected using a purposive sampling technique, from 131 adult patients weighing 70±3kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for this study. Third quartile values of the estimated LDRLs for CTDIw and DLP was determined as 10.9 mGy and 432.8 mCy*cm. The mean CTDIw obtained are lower to the reported data from the European Commission of 30mGy. The mean DLP are comparably lower than all the reported value from the European commission of 650mGy/cm. Therefore, there is no any clinical implication and hence CT dose optimization is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.