Traffic noise is a significant externality in urban areas that reduces the quality of life and may produce non-negligible effects on human health. The main factor responsible for traffic noise is individual transportation (cars and motorcycles) and the more congested the urban network, the higher the average level of traffic noise. An Urban Traffic Plan (UTP) is a tool for managing the urban mobility; in Italy the UTP is provided for under national laws and one of its objectives is noise abatement. The UTP manages the network (road directions, signal settings, etc.) without providing new infrastructures. In this paper, we test the effectiveness of UTPs in terms of noise abatement on a real case: the Urban Traffic Plan of Benevento. In this paper, we compare the estimated equivalent noise levels in several points of the town for the current scenario and for the (final) design scenario. Initial results show that, in order to evaluate the actual effectiveness of the UTP vis-à-vis traffic noise, some more comprehensive indicators have to be proposed: evaluating traffic noise reduction only in some points of the network cannot yield clear-cut results.
In the last years, new technical standards for the assessment of the energy efficiency of technical building systems were developed by the European Committee for Standardization (CEN). These procedures were conceived as to combine the easiness of the calculation methodologies and their related assumptions with a sufficient level of accuracy. While the former objective is often achieved, the latter is a challenging task as the procedures sometimes fail to simulate in a proper way the actual performance of the technical systems. On the other hand, the detailed procedures applied by detailed dynamic energy simulation tools are more precise and complex; however, for their application, they need a wide range of input data that are often hard to collect. For this reason, simplified procedures are now commonly applied, above all in the case of existing buildings. Nevertheless, these procedures need to be deeply analysed and validated. In this paper, the main standard calculation procedures addressed to chillers and specified in EN 16798-13:2017 were analysed, with a focus on the required input data and the calculation procedures. The same approach was then applied to the more detailed calculation methods used in the dynamic tools EnergyPlus and TRNSYS, and the results were compared. The theoretical analysis was then followed by a case study approach. A reference office building, representative of the Italian building stock, was selected and analysed in two different Italian climatic zones. The determination of the thermal energy need for cooling was performed by means of EnergyPlus, while the assessment of the energy demand related to technical building systems was performed both with EnergyPlus and with the standard procedures. This paper is part of a wider research activity finalised to the analysis of the technical building systems calculation procedures, taking into account different generation systems and thermal coupling modes between the technical systems and the building itself.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.