The currently used methods of sample preparation are examined and found to be unsatisfactory in case of counting methods for particle size analysis. It is the purpose of this paper to review the results of investigations of two different measuring principles (light extinction and electrical resistance change) by use of the same signal handling equipment. The commonly used techniques and units are compared with regard to the resulting density distributions of particle size below 0.25 mm. The final conclusions including recommendations to the use of ultrasonic treatment and to improvements of the sampling and the sample‐feeding units are valid for all counting methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.