we have used. Comparing the results obtained with counters {c') and {d') with the corresponding results obtained from (c) and (d), a small increase in the coincidence rate is noted. Considering the fact that the counters (c f ) and (d f ) are more sensitive to photons of low energy, the increase in the number of coincidences observed can be explained by the hypothesis that a fraction of the coincidences are due to the association between 7-radiation and x-rays subsequent to iT-capture. A sensible increase in N is obtained only for counters with KF (A?>-A^=0.48:db0.26) and not for those with KG, This agrees with the hypothesis that the increase is actually caused by x-rays of the K a line of argon which are strongly absorbed in chlorine.The hypothesis that there is an association between iT-capture and 7-radiation justifies the magnitude of the observed effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.