In the case of hemodynamically stable broad complex tachycardia, it is essential to evaluate the causes and to diagnose correctly in the selection of appropriate management and drugs. We report two neonates diagnosed with idiopathic ventricular tachycardia, which is extraordinarily rare. One presented with idiopathic fascicular ventricular tachycardia (right bundle branch block pattern with a superior axis), and the other presented with right ventricular outflow tract ventricular tachycardia (left bundle branch block pattern with an inferior axis). These two forms are representative of benign ventricular tachycardia. No features of cardiovascular shock were observed. While the recommended initial drug treatments are different, the conditions were well controlled by propranolol without the development of any adverse events. There was no recurrence of arrhythmia for several months in the outpatient clinic.
Purpose: In most neonatal intensive care units, echocardiography is performed at the bedside. The lack of closure of interatrial communications (IACs) in the oval fossa can affect mortality and morbidity. This study aimed to establish the rate of spontaneous closure of IACs diagnosed in the neonatal period and predict the need for subsequent evaluation according to various factors, including defect size and shape.Methods: The study group comprised 1,242 newborns admitted between March 2017 and December 2020. We judged the closure of the IACs and evaluated the risk factors of each. Patients were classified into the absence or presence of IACs. The morphology of the IACs was classified into atrial septal defects, patent foramen ovale, and multiple holes.Results: A total of 317 patients (131 female, 186 male) were enrolled in the study, and the average defect size was 3.0±1.0 mm. An overall spontaneous closure rate of 89.9% was observed during an average follow-up interval of 5.1±1.1 months. When multiple Cox regression analyses were performed to analyze the risk factors for spontaneous closure, initial defect size was a significant factor. The optimal cut-off value for predicting spontaneous closure of the IAC was 3.05 mm, and the area under the receiver operating characteristic curve was 0.625 (95% confidence interval, 0.520 to 0.729). Preterm infants had a larger defect size corrected for birth weight and a higher closure rate than term infants.Conclusion: Other than large defect size, no factors delayed spontaneous closure. When defects in the oval fossa measure ≤3 mm, most patients experience spontaneous closure by 7 months of age.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.