Objective: The purpose of this longitudinal study was to surveil the serum titanium ion levels at various time intervals in patients with indigenous 3D-printed total temporomandibular joint replacement (TMJ TJR). Study design: The study was conducted on 11 patients (male: 8; female: 3) who had undergone unilateral or bilateral TMJ TJR. Blood samples were drawn preoperatively (T0), 3 months (T1), 6 months (T2), and 1 year (T3) postoperatively. Data were analyzed and a p value of <0.05 was considered statistically significant. Results: The mean serum titanium ion levels at T0, T1, T2, and T3 was 9.34 ± 8.70 microgram/L (mcg/L), 35.97 ± 20.27 mcg/L, 31.68 ± 17.03 mcg/L, and 47.91 ± 15.47 mcg/L respectively. The mean serum titanium ion levels increased significantly at T1 (p= 0.009), T2 (p= 0.032), and T3 (p=0.00) interval. There was no significant difference between unilateral and bilateral groups. Conclusion: Serum titanium ion continued to show increased levels till the last follow-up of 1 year. These initial serum titanium ion levels increase is due to the initial wear phase of the prosthesis which manifests over 1 year. Further studies with large sample sizes and long-term follow-ups are required to see the deleterious effect if any on the TMJ TJR.
The purpose of this longitudinal study was to surveil the serum titanium ion levels at various time intervals in patients with indigenous 3D-printed total temporomandibular joint replacement (TMJ TJR). The study was conducted on 11 patients (male: 8; female: 3) who had undergone unilateral or bilateral TMJ TJR. Blood samples were drawn preoperatively (T0), 3 months (T1), 6 months (T2), and 1 year (T3) postoperatively. Data were analyzed and a p value of < 0.05 was considered statistically significant. The mean serum titanium ion levels at T0, T1, T2, and T3 was 9.34 ± 8.70 µg/L (mcg/L), 35.97 ± 20.27 mcg/L, 31.68 ± 17.03 mcg/L, and 47.91 ± 15.47 mcg/L respectively. The mean serum titanium ion levels increased significantly at T1 (p = 0.009), T2 (p = 0.032), and T3 (p = 0.00) interval. There was no significant difference between unilateral and bilateral groups. Serum titanium ion continued to show increased levels till the last follow-up of 1 year. These initial serum titanium ion levels increase is due to the initial wear phase of the prosthesis which manifests over 1 year. Further studies with large sample sizes and long-term follow-ups are required to see the deleterious effect if any on the TMJ TJR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.