We synthesized cesium lead-halide perovskite colloidal nanocrystals using the hot injection method for wide-color-gamut low-cost displays. An efficient surface defect passivation technique was applied to further improve the optical performance of the green and red perovskite nanocrystals. The prepared perovskite nanocrystal solutions were formulated into inkjet printable homogeneous inks and uniformly printed on the substrate with appropriate surface control. They formed the wide-color-gamut color conversion layers of quantum dot organic light-emitting diode displays. We confirmed the excellent photophysical properties of the synthesized green/red perovskite nanocrystals and the inkjet printed color conversion layers with a photoluminescence quantum yield of 99.7%/96.2% and a wide color reproduction range of 117%.
Objective:
To evaluate the outcomes and association factors of long-term hearing preservation (HP) in cochlear implantation with lateral wall (LW) electrode arrays.
Study Design:
Retrospective case review.
Setting:
Tertiary academic center.
Patients:
Thirty-four consecutive ears from 32 patients with a ≤ 80 dB HL preoperative low-frequency pure-tone average of 250 to 500 Hz were included.
Intervention:
Cochlear implantation with LW electrode arrays and the intention of achieving HP.
Main Outcome Measures:
HP classifications according to the HEARRING group and functional HP methods (≤ 85 dB HL of pure-tone threshold at 250 Hz) at 1 year postoperatively.
Results:
Based on the HEARRING classification, complete, partial, and minimal HP was achieved in 7 ears (21%), 12 ears (35%), and 4 ears (12%), respectively. Under functional classification, 14 ears (41%) exhibited functional hearing after surgery. The average threshold shift was 17.1 dB HL (SD = 16.9 dB HL). Among various clinical features, a ≤ 60 dB HL preimplant pure-tone threshold of 250 Hz was associated with HP outcome in both classifications (OR = 12.95, 95% CI = 1.29–130.01, p = 0.029 in HEARRING classification; OR = 14.36, 95% CI = 1.07–191.40, p = 0.044 in functional classification). The following parameters were not associated with HP (p > 0.05): patient demographics, surgical aspects (insertion route and depth), electrode array size, scalar electrode position, and presence of comorbidity.
Conclusion:
With LW electrode arrays, HP was achieved in 68% of HEARRRING group patients and 41% of functional classification patients. A ≤ 60 dB HL preimplant pure-tone threshold of 250 Hz was significantly associated with an increased rate of long-term HP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.