In this paper, the corrosion behaviour of thermal sprayed and diffusion‐coated materials are compared. The result of the high temperature corrosion test shows that the layers with NiCr applied by atmospheric plasma spraying (APS) and high velocity oxy fuel flame spraying (HVOF) are more resistant than the layers with NiCrBSi and Cr3C2/ NiCr. Furthermore, the layer with NiCr on 15 Mo 3 is more resistant than that on 13 CrMo 44 as base material. The corrosion behaviour of Al, Cr, and Cr/Si diffusion‐coated materials on 13 CrMo 44‐ are better than those same diffusion coatings on 15 Mo 3‐surfaces. In particular, the Cr diffusion‐coated materials show the highest corrosion resistances in this work. Also, the diffusion‐coated materials have higher resistances than thermal sprayed materials in HCl‐H2O‐O2‐N2‐atmosphere.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.