Unilateral recurrent laryngeal nerve palsy is a potential complication of the anterior approach for cervical surgery. It is a rare complication of radiotherapy to the neck. Only one case has been reported following radiotherapy apical lung cancer. It can result in unilateral vocal cord paralysis. We report a patient who demonstrated bilateral vocal cord paralysis immediately following right-sided anterior cervical surgery, with significant consequences, including aphonia, respiratory distress and subsequent takotsubo cardiomyopathy. She was diagnosed with acute, (temporary) post-operative right recurrent laryngeal nerve palsy, on the background of undetected and previously asymptomatic left recurrent laryngeal nerve palsy following radiotherapy for left apical lung cancer. The possibility of recurrent laryngeal nerve palsy should be considered in patients with previous apical lung cancer and/ or radiotherapy. Patents undergoing subsequent anterior cervical surgery should be considered for the appropriate precautions in the form of same-side surgery or pre-operative investigation for vocal cord paralysis.
Background: Total wrist arthrodesis is a well-established surgical technique that provides reliable pain relief in patients with advanced wrist disease. Key limitations of existing plating systems include hardware pull-out, hardware failure, and nonunion. There is limited literature on the newer style carpometacarpal joint (CMCJ) sparing plating system, produced by Medartis. The objective of this study was to determine the long-term clinical and radiological outcomes of wrist arthrodesis with a CMCJ sparing wrist plate. Methods: This study retrospectively identified 23 wrist arthrodeses using the Medartis CMCJ sparing plate for review. This study assessed the outcomes of 18 unilateral wrist fusions and 1 bilateral wrist fusion. The study group consisted of 12 men and 5 women with an average age of 56 years (range: 29-82 years) with a mean follow-up period of 17 months. Results: At the time of follow-up, all patients’ wrists had fused without postsurgical complication. The final grip strength in the operative hand was 28.2 kg/cm2, which was 87% of the contralateral side. The mean Quick Disabilities of the Arm, Shoulder, and Hand score at follow-up was 23.9, with all patients returning to daily living activities and work. Patients reported minimal pain (1.3/10), with almost all (17/18) satisfied with the outcome of the surgery and describing that they would recommend this procedure. Conclusion: Our case series highlights that the Medartis wrist arthrodesis plate is a newer design that is a well-tolerated option for wrist arthrodesis based on clinical assessment, functional hand assessment, and patient satisfaction, when compared with the existing literature on traditional plating systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.